Beka Hospitec AVERO Phoenix Operating Manual

Beka Hospitec AVERO Phoenix Operating Manual

Lifting bath tub

Advertisement

Operating manual
Original operating manual
AVERO Phoenix
Lifting bath tub
Version 2.1 / English
Subject to technical modifications
2020-11-17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVERO Phoenix and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beka Hospitec AVERO Phoenix

  • Page 1 Operating manual Original operating manual AVERO Phoenix Lifting bath tub Version 2.1 / English Subject to technical modifications 2020-11-17...
  • Page 2: Table Of Contents

    BEKA Hospitec GmbH Table of contents Imprint ........................4 Acknowledgement ................... 4 Manufacturer’s address ................... 4 TÜV quality seal ....................4 Introduction ......................5 Preface ......................5 Liability and warranty ..................5 The operating manual .................... 6 Validity ......................6 Type plate ......................
  • Page 3 Disposal of the product ................20 Troubleshooting/After-sales service ..............21 12.1 Troubleshooting help ...................21 Appendix ......................23 13.1 Technical data .....................23 13.2 Dimensions of the AVERO Phoenix 190 .............24 13.3 Dimensions of the AVERO Phoenix 170 .............25 13.4 Wiring diagram ....................26 13.5 Declaration of Conformity ................27 13.6 Accessories ....................28...
  • Page 4: Imprint

    1.1 Acknowledgement Dear customer, we would like to express our sincere thanks for the trust you have placed in us by purchasing this BEKA Hospitec GmbH product. Our products are manufactured and tested according to stringent quality criteria. 1.2 Manufacturer’s address BEKA Hospitec GmbH Am Rübenmorgen 3...
  • Page 5: Introduction

    The maintenance, inspection, assembly and installation as well as well as further technical interventions on the product must only be executed by BEKA Hospitec either by specialised companies authorised to this effect by BEKA Hospitec. The operation of the product as well as technical interventions on the product must only be carried out by specially trained personnel.
  • Page 6: The Operating Manual

    3.3 Description In this manual, the product is called lifting bath tub and (bath) tub. Operating manual AVERO Phoenix V2.1 E Page 6 of 35...
  • Page 7: Safety

    The manufacturer BEKA Hospitec shall not accept any liability for any damages, failures or faults caused by improper operation or handling.
  • Page 8: List Of Used Safety Instructions

    CE-label in accordance with the EC-Directive on Medical Devices. Solely intended for indoor use. Protection class I Do not put feet on the frame. IPX4 Protection against the penetration of liquids: Protection against water splashing from all directions. Operating manual AVERO Phoenix V2.1 E Page 8 of 35...
  • Page 9: Warnings

    ▪ Please make sure that your feet are not located beside the bath tub before and during the height adjustment procedure. WARNING Before the patient steps into the bath tub, the water temperature must be checked manually (without wearing gloves) either with a thermometer. Operating manual AVERO Phoenix V2.1 E Page 9 of 35...
  • Page 10: Transport

    After all fixations have been removed, you can lift the bath tub from the pallet (2 persons). The accessories for your bath tub are included in the supplied cardboard box. Operating manual AVERO Phoenix V2.1 E Page 10 of 35...
  • Page 11: Installation

    The connection of the bath tub must be executed in accordance with the technical drawings issued by BEKA Hospitec either the guidelines for the set-up and layout of wet areas and the current VDE standards. All supply and drain hoses as well as the electrical cables must be installed so as to avoid the danger of tripping.
  • Page 12: First Start-Up

    Only when these conditions are met, the manufacturer considers himself responsible for the impact on the safety, the reliability and the function of the device. In the event of a new connection of a AVERO Phoenix lifting bath tub, the technical data must be observed. WARNING...
  • Page 13: Operating Elements And Their Function

    Acrylic tub size reducer Air nozzles of the air spa system (optional) (optional) Temperature sensor for the Longitudinal grooves for inserting the bath bath water temperature size reducer Eccentric plug with tub outlet Operating manual AVERO Phoenix V2.1 E Page 13 of 35...
  • Page 14: Keypad For Operating The Bath Tub Functions

    5 and 1 simultaneously. The hand shower can at all times (even when the scalding protection is active) be switched off by pressing button 7. Operating manual AVERO Phoenix V2.1 E Page 14 of 35...
  • Page 15: Button Filling Height 1 And Filling Height 2

    If you do not shut off the filling of the tub manually, the water will overflow (the filling continues endlessly). Supervision of the caregiver is required throughout the manual Caution! filling. Operating manual AVERO Phoenix V2.1 E Page 15 of 35...
  • Page 16: The Display Screens

    If your bath tub features functions such as a disinfection system, a colour light therapy system, a sound system and/or an aromatherapy and air spa system, please observe the attached user manuals as well. Operating manual AVERO Phoenix V2.1 E Page 16 of 35...
  • Page 17: Operation

    The AVERO Phoenix lifting bath tub is free standing on three sides and requires only little space If you want to fill the AVERO Phoenix lifting bath tub, press button 8 or 9 on the control panel to start the filling of the bath tub.
  • Page 18: Cleaning/Disinfection

    9.1 Cleaning the lifting bath tub Clean the AVERO Phoenix with a soft, lint-free cloth, moistened with soapy water or a standard plastic cleaner. Please do not use abrasives to clean the bath tub! To avoid damages, no aerosol cleaners, sprays, abrasive cleaners or solvents must be used to clean the keypad.
  • Page 19: Checks/Tests

    Checks/tests Checks/tests In order to ensure a safe use of our AVERO Phoenix lifting bath tub and the protection of the users and the patients, BEKA Hospitec prescribes an annual safety check. The execution of the safety checks and maintenance must be documented and proven on request.
  • Page 20: Waste Disposal

    BEKA dealer, who will recycle the product in accordance with the locally applicable regulations and laws. For an environmentally-sound disposal, the company BEKA Hospitec GmbH will provide more information in its capacity of manufacturer. Please clean and disinfect the product prior to its disposal as well.
  • Page 21: Troubleshooting/After-Sales Service

    Check the filter as well as the inlet and outlet faucet for clogging. Too low a water flow rate. c) Check that the flow rate is sufficient for the supply conditions. d) Check if the connecting hoses are bent. Operating manual AVERO Phoenix V2.1 E Page 21 of 35...
  • Page 22 12 please contact the after-sales services of your dealer either the manufacturer. BEKA Hospitec GmbH Am Rübenmorgen 3 35582 Wetzlar Phone: +49(0)641-9 22 22-0 Fax: +49(0)641-9 22-22-20 info@beka-hospitec.de Operating manual AVERO Phoenix V2.1 E Page 22 of 35...
  • Page 23: Appendix

    - Atmospheric pressure: 800 – 1060 hPA Storage and transport - Temperature range: -20° C to 70° C - Relative humidity: 10% to 80%, non-condensing - Atmospheric pressure: 500 – 1100 hPA Operating manual AVERO Phoenix V2.1 E Page 23 of 35...
  • Page 24: Dimensions Of The Avero Phoenix 190

    Appendix 13.2 Dimensions of the AVERO Phoenix 190 Operating manual AVERO Phoenix V2.1 E Page 24 of 35...
  • Page 25: Dimensions Of The Avero Phoenix 170

    Appendix 13.3 Dimensions of the AVERO Phoenix 170 Operating manual AVERO Phoenix V2.1 E Page 25 of 35...
  • Page 26: Wiring Diagram

    Assemble hexagon-nipple, elbow 90°, ball valve, strainer and rosette (Details illustration Pos.1 und 2).  Wall drain DN 50, tile-even.  Junction-box (min. IP X5), 230 V/50 Hz, 1, 5 mm², fuse protection 16 A. Operating manual AVERO Phoenix V2.1 E Page 26 of 35...
  • Page 27: Declaration Of Conformity

    Appendix 13.5 Declaration of Conformity Operating manual AVERO Phoenix V2.1 E Page 27 of 35...
  • Page 28: Accessories

    Shower hose for disinfection (yellow) L = 2.0m 13.6.1 Spare parts/consumables Spare parts or consumables are available upon request from your BEKA Hospitec dealer or directly from the manufacturer. Please note: You cannot exchange and replace all spare parts by yourself.
  • Page 29: Electromagnetic Compatibility

    Guidance and manufacturer’s declaration - electromagnetic immunity (Table 201) The AVERO Phoenix been designed for use in the hereafter listed ELECTROMAGNETIC ENVIRONMENTS. The customer or the user of the AVERO Phoenix must ensure that the appliance is used in such environment.
  • Page 30 Guidance and manufacturer’s declaration - electromagnetic immunity (Table 202) The AVERO Phoenix been designed for use in the hereafter listed ELECTROMAGNETIC ENVIRONMENTS. The customer or the user of the AVERO Phoenix must ensure that the appliance is used in such environment.
  • Page 31 Guidance and manufacturer’s declaration - electromagnetic immunity (Table 204) The AVERO Phoenix been designed for use in the hereafter listed electromagnetic environments. The customer or the user of the AVERO Phoenix must ensure that the appliance is used in such environment. Immunity...
  • Page 32 Recommended distance between portable and mobile communications equipment and the AVERO Phoenix (Table 206) The AVERO Phoenix is intended for use in an electromagnetic environment with controlled HF interferences. The customer or the user of the AVERO Phoenix can avoid electromagnetic...
  • Page 33: Journal

    According to §13 of the Medical Device Directive, you are compelled to keep a journal for this device. You can use this journal as template. Journal Device: AVERO Phoenix Manufacturer: BEKA Hospitec GmbH, Am Rübenmorgen 3, 35582 Wetzlar Serial number: _____________________________________________ Date of purchase: _____________________________________________ Site: _____________________________________________...
  • Page 34 Appendix Periodic inspection, repair, DGUV-3, safety check, etc. Type of Date Result Measure Signature: inspection Operating manual AVERO Phoenix V2.1 E Page 34 of 35...
  • Page 35 BEKA Hospitec GmbH ●Am Rübenmorgen 3 ●35582 Wetzlar Germany● Phone/Fax:+49(0)6 41-9 22 20-0...

Table of Contents