Installing the Irrigation Valve
without a Valve Box :
3
7
8
18
3. Install the valve box with the top edge of the box at ground
level.
This avoids damage when mowing the lawn.
Please refer to the relevant operating instructions for information
on how to install the Irrigation Valves in GARDENA Valve Boxes
V1 and V3.
The integrated solenoid valve works only correctly with the
Irrigation Valve connected in flow direction.
Flow direction
A
V Pay attention to the flow direction (arrows) when
installing the Irrigation Valve
v Seal the screw connections with PTFE sealing tape, Art. 7219.
Connecting GARDENA Connecting pipes
2705 / 2718) or other commercially available connecting pipes :
7
8
1. Screw a GARDENA Connector
2769 (5 /4 " = 32 mm) into the Irrigation Valve
2. Connect the GARDENA connecting pipes
cially available connecting pipes (25 mm / 32 mm).
3
.
8
(2700 / 2701 / 2704 /
2763 (1 " = 25 mm) /
7
3
.
8
or other commer-