Removal and replacement

Bosch Rexroth Corporation, A21VG Series 10, RE 93223-01-B/09.2020
11 Removal and replacement

11.1 Required tools

Removal can be performed with standard tools. No special tools are necessary.

11.2 Preparing for removal

Decommission the entire system as described in the instruction manual for the
1.
machine or system.
– Relieve pressure in the hydraulic system according to the instructions of the
machine or system manufacturer.
– Make sure that the relevant system components are not under pressure or
voltage.
Protect the complete system against being energized.
2.

11.3 Removal of the axial piston unit

Proceed as follows to remove the axial piston unit:
Check whether the hydraulic system is depressurized.
1.
Allow the axial piston unit to cool down until it can be removed without danger.
2.
For below-reservoir installation, before removing the axial piston unit from the
3.
complete system, seal the connection to the reservoir or drain the reservoir.
Place a drip tray under the axial piston unit to collect any hydraulic fluid that
4.
may escape.
Loosen the lines and collect the escaping hydraulic fluid in the drip tray.
5.
Remove the axial piston unit. Use a suitable lifting device.
6.
Completely empty the axial piston unit.
7.
Plug all openings.
8.

11.4 Preparing the components for storage or further use