Installation
33/56
2
1
Fig. 9: Removing transport protection
1 Protection plug/threaded plug
2 Protection cover
Ports intended for connecting lines are covered by protection plugs or threaded
plugs, which serve as transport protection. All ports required for functional
operation must be connected (see Table 10 "Ports A21VG series 10 1)" on
page 36). If this requirement is disregarded, malfunction or damage may
result. If a port is not connected, it must be plugged with a threaded plug
because protection plugs are not pressure-resistant.
The setting screws are protected against unauthorized resetting by means of
protection caps. Removing the protection caps will void the warranty. If you
need to change settings, contact your responsible Bosch Rexroth Service
partner (for address, see chapter 10.5 "Spare parts" on page 45.
3.
For versions with through drive, install the auxiliary pump according to the
pump manufacturer's instructions.
RE 93223-01-B/09.2020, A21VG Series 10, Bosch Rexroth Corporation