Performance Characteristics
9.3

Measured Value Resolution

Dead band as per EN61298-2:
• Digital: 1 mm (0.04 inch)
• Analog: 4 μA
9.4

Response Time

The response time can be configured. The following step response times apply
(in accordance with DIN EN 61298-2) when damping is switched off:
Tank height
< 20 m (66 foot)
Sampling rate
-1
1 s
Response time
< 3 s
In accordance with DIN EN 61298-2, the step response time is the time following an abrupt
change in the input signal up until the changed output signal has adopted 90 % of the
steadystate value for the first time.
9.5

Influence of Ambient Temperature

The measurements are carried out in accordance with EN 61298-3
Digital (HART, Bluetooth® wireless technology):
Standard version: average T
Analog (current output):
Zero point (4 mA): average T
Span (20 mA): average T
20
= ±3 mm (±0.12 inch)/10 K
C
= 0.02 %/10 K
C
= 0.05 %/10 K
C