Output; Output Signal; Digital Output Hart; Signal On Alarm - Pepperl+Fuchs LCR20 Technical Information

Level radar
Table of Contents

Advertisement

Level Radar LCR20

Output

6
Output
6.1

Output Signal

Output signal 4 to 20 mA
An 4 to 20 mA interface is used for measured value output and to power to the device.
6.2

Digital Output HART

Signal encoding; FSK ±0.5 mA over current signal
Data transmission rate; 1200 Bit/s
Bluetooth
The device has a Bluetooth
and configured via this interface using the P+F Level app.
The range under reference conditions is 25 m (82 foot).
Incorrect operation by unauthorized persons is prevented by means of encrypted
communication and password encryption.
The Bluetooth
6.3

Signal on Alarm

Depending on the interface, failure information is displayed as follows:
Current output
Alarm current: 22.5 mA (in accordance with NAMUR recommendation NE 43)
Operating tool via digital communication (HART) or P+F Level (app)
Status signal (as per NAMUR Recommendation NE 107)
Plain text display with remedial action
6.4

Linearization

The linearization function of the device allows the conversion of the measured value into any
unit of length, weight, flow or volume. When operating via PACTware and linearization tables
for calculating the volume are preprogrammed in the vessels.
Pre-programmed linearization curves
Horizontal cylindrical tank
Sphere
Tank with pyramid bottom
Tank with conical bottom
Tank with flat bottom
Other linearization tables of up to 32 value pairs can be entered manually.
14
®
®
Wireless Technology (available as an optional extra)
®
wireless technology interface and can be operated
®
wireless technology interface can be deactivated.