Outdoor Control Mode - Hisense T1 Series Technical & Service Manual

Floor standing type air conditioner
Table of Contents

Advertisement

6
.
C
O
N
T
R
O
L
M
O
D
6
.
C
O
N
T
R
O
L
M
O
D
6-2 Outdoor mode control
Control function
1.Cooling Anti-freeze Protection
To prevent indoor air conditioner evaporator temperature is too low, the indoor coil
sensor for real time detection of evaporator. If the indoor coil temperature is too low, the
compressor will protect.
2. Overload Protection
Air can heat exchanger temperature sensor for monitoring, when the sensor when
the temperature is too high, the compressor will be automatic protection
3. Exhaust temperature protection
To prevent deterioration due to high exhaust temperature of compressor, the
machine will realize the real-time detection of the temperature of exhaust gas. If the
temperature is too high compressor automatic protection
4.Operation Mode
Air conditioning mode is the operation mode set by users through remote controller,
four modes are available: cooling, heating, dehumidification, as well as fan mode.
5. Four-way Valve Control
Four-way valve of the outdoor machine shuts down when cooling and defrosting
but starts when heating. During the heating process, the four way valve to stop working for a
period of time after compressor disconnect.
6. Start-up Protection:
FLOOR STANDING AIR CONDITIONER TECHNICAL& SERVICE MANUAL V3.2