Dispense Valve - Bunn Single Operating & Service Manual

Bunn single: user guide
Hide thumbs Also See for Single:
Table of Contents

Advertisement

SERVICE (cont.)

DISPENSE VALVE

22978.0000
FIG. 9 DISPENSE VALVE
Location:
Dispense valve is located inside the hood directly
above the sprayhead.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the wires from the dispense valve and
check the voltage across the white/violet wire and
white/green wire. Connect brewer to the power
source. Place the "ON/OFF" Switch in the "ON"
position and press and release the Start Switch.
The indication must be:
a.) 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models.
b.) 200 to 240 volts ac for two wire 200 or 240
volt models.
3. Disconnect brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wiring
Diagrams and check the brewer wiring harness.
4. Check for continuity across the dispense valve coil
terminals.
If continuity is present as described, reconnect the
wires to the dispense valve and proceed to #5.
If continuity is not present as described, replace the
dispense valve.
5. Check the dispense valve for coil action. Connect
the brewer to power source. Place the "ON/OFF"
Switch in the "ON" position and press and release
the Start Switch. Listen carefully in the vicinity of
the dispense valve for a "clicking" sound as the
coil magnet attracts and repels the plunger.
6. Disconnect the brewer from the power source.
If the sound is heard as described, there may be a
blockage in the dispense valve or the water line to the
sprayhead. Remove the dispense valve and inspect for
wear, and remove waterborne particles.
If the sound is not heard as described, replace the
dispense valve.
Removal and Replacement:
P816
1. Disconnect wires from dispense valve.
2. Drain enough water from the tank so the dispense
valve is above the water line.
3. Remove water lines and hose barb fitting from
dispense valve.
4. Remove dispense valve from the sprayhead
panel.
5. Install new dispense valve .
6. Reconnect the water lines, hose barb fitting and
the wires to the dispense valve.
7. Refer to Fig. 10 when reconnecting wires.
FIG. 10 DISPENSE VALVE TERMINALS
Page 22
WHI/VIO to Timer TL1
WHI/VIO to ON/OFF Switch
WHI/RED to Brew Selector Switch
WHI/GRN to Timer TL4
WHI/GRN to By-Pass Valve
P829
27038 030901