Remote Power Switch Configuration Option - Maple Systems OMI6800B Series Operation Manual

Light industrial panel pc
Table of Contents

Advertisement

Operations Manual: OMI6800B Series

REMOTE POWER SWITCH CONFIGURATION OPTION

By default, your OMI6800B Series unit is configured to boot up automatically upon application of power,
with no configuration changes necessary. In the event that DC power is lost, the unit will automatically
boot up again once DC power is restored.
If you wish to control the unit's on/off status via a Remote Power Switch, simply connect a normally open
momentary-type switch wired to the included 2-pin connector. The connector plug accepts min. 28AWG
and max. 20AWG solid or stranded wire connection, with push-type insertion.
When the unit is powered, pressing the switch will perform a proper Windows shut down. If the DC power
supply to the OMI6800B Series is still providing power, simply press your power switch again to boot your
OMI6800B Series unit. When the unit is properly shut down, then it is safe to remove DC power. When DC
power is provided to the OMI6800B Series once again, the unit will automatically boot.
Warning: Maple Systems does not recommend shutting down the
Always perform a Windows Shut Down procedure when you wish to turn the unit off.
Cutting DC power to the OMI6800B Series can corrupt the Windows Operating System,
or other software or hardware components of your OMI. Damage caused by improper
application or removal of power may not be covered under the OMI6800B Series
Warranty.
Operations Manual: OMI6800B Series
OMI6800B Series by cutting DC power to the unit.
17
17

Advertisement

Table of Contents
loading

Table of Contents