Wiring Diagram for Connectors 7 through 10

Figure 2: PW-7000 Output Module: Connectors 7-10
10
PW-7000 Output Module (PW7K1OUT) Installation Guide, Document 800-25675V1
RS-485 Com Bus
Cable From Dif.
Panel (Remote
Mount Only)
Connect to
chasis GND at
one side
RS-485 TR+
ONLY !
RS-485 TR-
RS-485 GND
NC
+ 12V
GND
16 OUTPUT BOARD
1
2
1
3
2
4
3
5
6
1
2
1
3
2
4
3
5
4
6
5
6
1
1
2
2
3
3
4
5
4
6
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
J 1 - RS-485
Termination
1
2
3
4
5
Tamper Switch
(In CLOSED
position when
Cabinet Door is
Closed)
+12VDC Power
TMP
GND
C - No Charging
PFL
N/C - No Charging
RELAY12 NC
RELAY12 C
RELAY12 NO
RELAY13 NC
PWR +
RELAY13 C
+
_
RELAY13 NO
PWR -
DC Output
RELAY14 NC
RELAY14 C
RELAY14 NO
RELAY15 NC
RELAY15 C
RELAY15 NO
The connectors on
this side of the board
are not accessible
when it is rack
mounted.