Bunn CDBC Operating & Service Manual page 21

Bunn cdbc: user guide
Table of Contents

Advertisement

The bank of temperature indicators indicates that a fault exists. Count the number of flashes between pauses and
use this chart as a guide to investigating the fault.
FLASHES CAUSE
1
Dry Plug - In Fault -
Sheath of temperature probe dry for 10 minutes after power-up
2
Low Tank Level Fault -
Level probe dry for 7 minutes after fill valve is energized
3
Low Water Temperature Fault -
Sensor in tank is calling for heat for 30 minutes or more
4
Tank Sensor Disagreement -
Level probe detects water, but dry plug-in probe dry
5
Temp Sensor Out-of-Range - High
6
Temp Sensor Out-of-Range - Low
DIAGNOSTICS
THINGS TO CHECK
Water Pressure (Is water shut "OFF")
Temperature probe wiring
Fill valve wiring, function, & strainer
Green wire between tank and circuit board
Water pressure (Is water shut "OFF")
Level probe wiring
Temperature probe wiring
Fill valve wiring, function, & strainer
Tank heater wiring & function
Temperature probe wiring
Temperature probe wiring
Level probe wiring
Green wire between tank and circuit board
Sensor not connected to circuit board
Sensor wires shorted together or to chassis
Page 21
35582 041503

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

CdbcfCdbcfpCdbcpSingle cdfSingle cd

Table of Contents