Kyoritsu Electrical Instruments Works KEW 6310 Quick Manual

Kyoritsu Electrical Instruments Works KEW 6310 Quick Manual

Power quality analyzer

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Quick manual
POWER QUALITY ANALYZER
KEW 6310

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KEW 6310 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kyoritsu Electrical Instruments Works KEW 6310

  • Page 1 All manuals and user guides at all-guides.com Quick manual POWER QUALITY ANALYZER KEW 6310...
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com Contents KEW6310 ●Preface   This Quick manual is a simplified version of the full instruction manual which can be found in the supplied This manual is intended only as a handy reference guide and should only CD-ROM.
  • Page 3: 1.Instrument Overview

    All manuals and user guides at all-guides.com KEW6310 Instrument Overview 1.Instrument Overview Feature   This is a Clamp-type Power Quality Analyzer that can be used for various wiring systems. It can be used for simple measurements of instantaneous/ integration/ demand values, and also for monitoring waveforms and vectors, analyzing harmonics and measuring fluctuations in supply voltages and for the simulation of power factor correction with capacitor banks.
  • Page 4 All manuals and user guides at all-guides.com Functional Overview KEW6310 Functional Overview Instantaneous value measurement Measures average/max/min values of instantaneous values of current, voltage and electric power. See (Section 5) W Range for further details. Integration value measurement Measures active/ apparent/ reactive powers on each CH. See (Section 6) Wh Range for further details.
  • Page 5 All manuals and user guides at all-guides.com KEW6310 Functional Overview Measurement at WAVE Range Displays vector / waveform of voltages and currents per CH See (Section 8) WAVE Range for further details. Harmonic measurement Measures / analyzes harmonic components of current & voltages See (Section 9) Harmonic Analysis for further details.
  • Page 6: 2.Instrument Layout

    All manuals and user guides at all-guides.com Instrument Layout KEW6310 2.Instrument Layout PRINT SCREEN Front view Save the displayed screen as BMP files Function Execute the displayed DATA HOLD KEY LOCK ╱ function Hold the readings. * Measurement continues even if  screen is frozen.
  • Page 7 All manuals and user guides at all-guides.com KEW6310 Connector Connector Voltage Input Terminal (VN, V1, V2, V3) Current Input Terminal (A1, A2, A3, A4) Terminal Cover Power Connector Side face <When the Connector Cover is closed> <When the Connector Cover is opened> CF Card Cover CF Card Slot USB Connector...
  • Page 8: 3. Getting Started

    All manuals and user guides at all-guides.com Getting Started KEW6310 3. Getting Started   The KEW6310 operates with either an AC power supply or batteries. In the event of AC power interruption, power to the instrument is automatically restored by the batteries in the instrument. Dry- cell batteries (alkaline) and rechargeable ones (Ni-MH);...
  • Page 9 All manuals and user guides at all-guides.com KEW6310 Charging the rechargeable Ni-MH batteries Charging the rechargeable Ni-MH batteries   Following message to prompt battery charge appears on the LCD automatically when battery level is 40% or less at starting the instrument. Press the Cursor Keys and ENTER...
  • Page 10 All manuals and user guides at all-guides.com Cord Connection KEW6310 Cord Connection Voltage Test Leads Match the arrow marks Power Cord Clamp Sensor Rated supply voltage : 100 ~ 240VAC (±10%) Rated supply frequency : 45 ~ 65Hz Max power consumption : 20VAmax Start-up Screen  ...
  • Page 11: 4.Setting

    All manuals and user guides at all-guides.com KEW6310  Setting 4.Setting The SET UP consists of following 4 settings. Basic Setting : Setting of the items common to all measurements Measurement Setting : Setting of each measurement Save Setting : Setting of data save methods Other Setting : Environmental setting Press the Cursor...
  • Page 12 All manuals and user guides at all-guides.com Basic Setting  KEW6310 Basic Setting Setting item Details of Setting ①1P2W×1 ②1P2W×2 ③1P2W×3 ④1P2W×4 ⑤1P3W×1 ⑥1P3W×2 ⑦1P3W×1+2A ⑧3P3W×1 ⑨3P3W×2 Wiring ⑩3P3W×1+2A ⑪3P3W3A ⑫3P4W×1 ⑬3P4W×1+1A ⓪4A 150V╱ 300V ╱600V╱1000V Voltage Range VT Ratio 0.01~9999.99( 1.00 ) 8128:1╱5╱10╱20╱50A╱AUTO 8127:10╱20╱50╱100A╱AUTO 8126:20╱50╱100╱200A╱AUTO...
  • Page 13 All manuals and user guides at all-guides.com KEW6310  Basic Setting Orientation of Clamp sensor Load Arrow mark: Points towards load side Power Supply Reverse clamping switches the symbols (+/-) for active power. − 12 − KEW6310...
  • Page 14 All manuals and user guides at all-guides.com Measurement Setting  KEW6310 Measurement Setting Setting Item Details of Setting Instantaneous/avg/max/min values ON╱OFF Detailes W╱Wh╱ 1.000mW~999.9TW ( 300.0kW ) Target demand DEMAND* Shorter than intervals, 3 different cycles are Demand inspection cycle available. ( 10 min ) WAVE Save item ON╱OFF...
  • Page 15 All manuals and user guides at all-guides.com KEW6310  Save / Other Setting Measurement Setting Setting Item Details of Setting 1sec╱2sec╱5sec╱10sec╱15sec╱20sec╱30sec╱ Interval 1min╱2min╱5min╱10min╱15min╱20min╱ 30min ╱1hour * Interval can be selected at W, Wh, DEMAND, WAVE, Harmonic analysis, Swell/ Dip/ Int, Transient, Inrush current, Unbalance ratio and Capacitance Ranges.
  • Page 16: 5.Instantaneous (Inst) Value Measurement

    All manuals and user guides at all-guides.com Instantaneous value measurement  KEW6310 5.Instantaneous (Inst) value measurement Steps for measurement     Ensuring your safety Range Basic Setting Measurement setting Save Setting        ↓ Wiring Interval Recording method  Preparation for measurement V Range Save item (W) Recording start VT Ratio ・Inst value...
  • Page 17 All manuals and user guides at all-guides.com KEW6310  Instantaneous value measurement Header of the saved data A V G _ A 1 [ A ] _ 1 INST : Instantaneous value   ① Average value : ︸        ︸  ︸   ︸      ︸ Max value :...
  • Page 18: 6.Integration Value Measurement

    All manuals and user guides at all-guides.com Integration value measurement  KEW6310 6.Integration value measurement Steps for measurement Range     Ensuring your safety Basic Setting Measurement setting Save Setting Wiring Interval Recording method         ↓ V Range Save item (Wh) Recording start  ...
  • Page 19 All manuals and user guides at all-guides.com KEW6310  Integration value measurement Header of the saved data INTEG Integration value : ① INTEG_WP+[Wh]_1   Active power energy (consumption) : ② Active power energy (regenerating) : ︸        ︸     ︸...
  • Page 20: 7.Demand Measurement

    All manuals and user guides at all-guides.com Demand measurement   KEW6310 7.Demand measurement   Steps for measurement Range    Ensuring your safety Basic Setting Measurement setting Save Setting         ↓ Wiring Interval Recording method  Preparation for measurement V Range Save item (W) Recording start VT Ratio ・Inst value...
  • Page 21 All manuals and user guides at all-guides.com KEW6310  Demand measurement Header of the saved data INTEG : Integration value ① INTVL : Variation in interval INTVL_WP+[Wh]_1 : Sum of demand value   TARGET : Target value ︸       ︸     ︸...
  • Page 22 All manuals and user guides at all-guides.com Demand measurement  KEW6310 Measurement Screen Remaining time (Time left) Target value Demand interval is counted down. S h o u l d b e s e t f o r each measurement. Predicted value Predicted demand value when preset demand interval elapses under present load.
  • Page 23 All manuals and user guides at all-guides.com KEW6310  Demand measurement Demand change Measured max demand with time & date information Demand value is displayed with recorded time & date info Cursor where cursor is placed. Cursor Use the to move the cursors. Target demand Bar graph White bar : Percentage of...
  • Page 24: 8.Wave Range

    All manuals and user guides at all-guides.com WAVE Range  KEW6310 8.WAVE Range Steps for measurement     Ensuring your safety Range Basic Setting Measurement setting Save Setting        ↓ Wiring Interval Recording method   Preparation for measurement V Range Save item Recording start VT Ratio Recording termination...
  • Page 25 All manuals and user guides at all-guides.com KEW6310  WAVE Range Header of the saved data  File ID : 6310-04 (Waveform data) ① 1 〜 128 : Sampling sequence 5/133     ② 129 〜 256 : ditto (① + 128) ︸  ...
  • Page 26: 9.Harmonic Analysis

    All manuals and user guides at all-guides.com Harmonic Analysis  KEW6310 9.Harmonic Analysis Steps for measurement Range    Ensuring your safety Basic Setting Measurement setting Save Setting         ↓ Wiring Interval Recording method V Range THD calculation Recording start   Preparation for measurement VT Ratio Allowable range Recording termination...
  • Page 27 All manuals and user guides at all-guides.com KEW6310  Harmonic Analysis   Save data File ID : 6310-06 Saved time & date ELAPSED TIME Channel Total THD Inst at each order 1_[V/A] 〜 1_[deg] 〜 DATE TIME ELAPSED TIME TOTAL 63_[V/A] 63_[deg] yyyy/mm/dd h:mm:ss...
  • Page 28: 10.Power Quality

    All manuals and user guides at all-guides.com Swell / Dip / Int measurement  KEW6310 10.Power Quality Swell / Dip / Int measurement Steps for measurement Range Measurement setting Save Setting     Ensuring your safety Swell / Dip / Int Measurement Recording method        ...
  • Page 29 All manuals and user guides at all-guides.com KEW6310  Swell / Dip / Int measurement Duration Max / Min Data DURATION MAX/MIN --:--:--.-- h:mm:ss.ss (±)x.xxxE±nn start max(Swell) min(Dip/Int) (±) value x 10 ±10 File ID : 6310-13 Saved time & date ELAPSED TIME Instantaneous Average...
  • Page 30: Transient Measurement

    All manuals and user guides at all-guides.com Transient measurement  KEW6310 Transient measurement Steps for measurement    Ensuring your safety Range         ↓ Measurement setting Save Setting   Preparation for measurement Transient measurement Recording method Interval Recording start         ↓ V Range Recording termination       Setting Threshold value...
  • Page 31 All manuals and user guides at all-guides.com KEW6310  Transient measurement Save data File ID : 6310-08 Saved time & date Data DATE TIME 201 data yyyy/mm/dd h:mm:ss.ss (±)x.xxxE±nn year/month/ date hour:min:sec Max (Peak) (±) value x 10 ±n File ID : 6310-14 Saved time &...
  • Page 32: Inrush Current Measurement

    All manuals and user guides at all-guides.com Inrush Current Measurement  KEW6310 Inrush Current Measurement Steps for measurement Range     Ensuring your safety Measurement setting Save Setting Inrush Current Measurement Recording method         ↓ Interval Recording start   Preparation for measurement Clamp sensor Recording termination A Range...
  • Page 33 All manuals and user guides at all-guides.com KEW6310  Inrush Current Measurement Save data File ID : 6310-09 Saved time & date Start / End Duration Max / Min Data DATE TIME I╱O DURATION MAX/MIN 201 data yyyy/mm/dd h:mm:ss.ss 1╱0 -:--:--.-- h:mm:ss.ss (±)x.xxxE±nn year/month/ date hour:min:sec Start End Start to End Start...
  • Page 34: Unbalance Ratio

    All manuals and user guides at all-guides.com Unbalance Ratio  KEW6310 Unbalance Ratio Steps for measurement Range    Ensuring your safety Basic Setting Measurement setting Save Setting Wiring Unbalance Ratio Recording method         ↓ V Range Interval Recording start   Preparation for measurement VT Ratio Output threshold Recording termination Clamp...
  • Page 35 All manuals and user guides at all-guides.com KEW6310  Unbalance Ratio Header of the saved data INST : Instantaneous value AVG_A1[A]_1 ①    : Average value : Max value ︸        ︸ ︸   ︸   ︸ : Min value    ...
  • Page 36: Flicker

    All manuals and user guides at all-guides.com Flicker  KEW6310 Flicker * An optional voltage sensor KEW8325F is required for Flicker measurement. Steps for measurement Range    Ensuring your safety Measurement setting Save Setting         ↓ Flicker Recording method   Preparation for measurement V Range Recording start        ...
  • Page 37 All manuals and user guides at all-guides.com KEW6310  Flicker (1min) − 36 − KEW6310...
  • Page 38: Capacitance Calculation

    All manuals and user guides at all-guides.com Capacitance Calculation  KEW6310 Capacitance Calculation - Sizing of capacitor banks for Power factor correction (PFC) Steps for measurement Range     Ensuring your safety Basic Setting Measurement setting Save Setting         ↓ Wiring Capacitance Recording method V Range Interval...
  • Page 39 All manuals and user guides at all-guides.com KEW6310  Capacitance Calculation Header of the saved data AVG_A1[A]_1 INST : Instantaneous value ①    : Average value ︸ : Max value        ︸ ︸   ︸   ︸     ①   ② ③ ④   ⑤ :...
  • Page 40: 11.Cf Card / Saved Data

    All manuals and user guides at all-guides.com CF Card / Saved data KEW6310 11.CF Card / Saved data CF Card (operation check has completed) Capacity 32MB 64MB 128MB 256MB 512MB SanDisk Corp.* SDCFB-32 SDCFB-64 SDCFB-128 SDCFB-256 SDCFB-512 SDCFG-1 AD-CFX Adtec co., Ltd. AD-CFG32 AD-CFG64 AD-CFG128...
  • Page 41 All manuals and user guides at all-guides.com KEW6310 Data transfer Data transfer    D ata in the CF card or internal memory can be transferred to a PC via USB connection or CF card reader. Transfer to PC via: Card reader CF card data (file) △* ○...
  • Page 42 All manuals and user guides at all-guides.com File format and name KEW6310 Configuration file  File Name : ME 000123 .KAS CF:CF card Save in ①          ①   ②    ③ ME:Internal memory File No 000000 〜 999999 ② Extension ③ Bitmap file Save item PS : Print screen ①...
  • Page 43: 12. Wiring Check

    All manuals and user guides at all-guides.com 12. Wiring check  Proper wirings can be checked at WAVE Range. 1. Ordinal screen 2. Checking wiring 3. Check completes Wiring check starts. Wiring check completes. Press the Key. In case of NG, Error message appears.

Table of Contents