Mitsubishi MJ-E16V-S1 Service Manual page 15

Table of Contents

Advertisement

<Operation Control>
1 Specifications shared at all operation modes
The compressor and blower fan will operate for about 6 minutes after turning on the operation switch or
activating the compressor, regardless of humidity or temperature levels.
2 Low, Low Temp, Air Purifier
Compressor
Low
ON
Laundry
ON
Low Temp
ON
Air Purifier
OFF
3 Easy Dehumidifier
Temperature
Current humidity
Temperature table
– Set humidity
Set humidity
Dehumidification
Fan rank
Compressor
+5%
+3%
Fan rank
Compressor
+1%
–1%
Fan rank
Compressor
1. Controls
(a) Adjusts humidity according to room temperature for increased comfort.
(b) CIRCULATION mode is activated when the temperature is high and the humidity is low. This mode keeps the
compressor off.
Target part Compressor
Operation
ON/OFF
(c) Switches temperature table every 60 seconds to prevent the blower from turning on and off at the 3-minute restart for
the coloured section in the chart above. (51% – 59%)
(d) When the room temperature is above 29°C (temperature rising) or 27°C (temperature decreasing), CIRCULATE
mode operates with the humidity below 50%.
(e) The unit activates the dehumidifier when the humidity rises above 60%, and returns to CIRCULATE mode when the
humidity drops below 50%.
Set humidity 60%
60%
50%
Humidity
Temperature
ON
Compressor
OFF
ON
Blower
OFF
Humidity
60%
50%
2. Easy DEHUMIDIFYING mode is disabled in the following cases.
(a) The MODE button is used to activate the previously set mode (AIR PURIFIER, LOW, AUTO, LAUNDRY, LOW TEMP).
(b) The DRYING INSIDE button is used to activate DRYING INSIDE mode.
Fan temperature table
16°C
14°C
27°C
Rank 1
Rank 1
Rank 3
Rank 4
Rank 6
Rank 1
Rank 1
Rank 1
22 C
20 C
27 C
0
1
60%
50%
Dehumidifier mode
Dehumidifier mode
Rank 1
Rank 1
ON
ON
Rank 1
Rank 1
ON
ON
Rank 0
Rank 0
OFF
OFF
Airflow fan
Solenoid valve
Rank control
OFF
Circulate
set humidity 60%
Set humidity 50%
~20°C~
~27°C~
Set humidity
When 60% exceeded,
60%
lowers to below 50%
Set humidity
50%
Compressor
Compressor
OFF
OFF
Fan rank 0
Fan rank 0
20°C
27°C
29°C
36°C
34°C
Rank 2
Rank 5
Rank 5
Rank 4
Rank 2
Rank 5
Rank 1
Rank 1
29 C
34 C
2
60%
50%
Circulate
Dehumidifier mode
Rank 2
To
ON
Dehumidifier
Rank 2
mode
ON
Rank 4
To
Circulate
OFF
mode
Louvre
ON/OFF
Dehumidifier mode
Circulate
set humidity 50%
set humidity 60%
CIRCULATE mode
Room
temperature
36 C
3
60%
50%
Circulate
Dehumidifier mode
Rank 5
To
ON
Dehumidifier
Rank 5
mode
ON
To
Rank 5
Circulate
OFF
mode
15