Table of Contents

Advertisement

Available languages

Available languages

Water circuits sanitization
1.
Turn off the water supply and press on the buttons to remove the pressure.
2.
Disconnect the filter. Put a SANIPURE dose (or equivalent) inside the Filtropure inline jigger.
3.
Connect the inline jigger in place of the filter.
4.
Switch on the cooler. Open the water supply and circulate the water inside the circuits.
5.
Make the water circulate and let act 5 minutes. Proceed to a draining in order to eliminate the
solution. Use the test strips for being sure that the water is clear.
Use the test strips for being sure that the water is clear.
For sparkling versions: empty one liter of water more via the «sparkling water» button to replace the
entire water inside the carbonator. Leave for 5 minutes th disinfection product and rinse at least 10
liters of wa ter.
Descaling (hot versions)
We recommend to descale the cooler's hot tank, every 1 or 2 years, depending on the hardness of
water.
1.
Turn off the water supply and press on the buttons to remove the pressure.
2.
Disconnect the filter. Put a PURICAL dose (or equivalent) inside the Filtropure inline jigger.
3.
Connect the inline jigger in place of the filter. Switch on the cooler. Open the water supply .
4.
Make the water circulate and let act 10 minutes. Proceed to flushing (3 liters).
Water filter replacement
The water cooler is equiped with a 5000 litres triple action filter (in option). To indicate that it needs to be replaced, an indicator light
switches on ; henceforth, here is the procedure to follow :
1.
Turn off the water supply and press the cold water button on the control panel to remove the pressure.
2.
Unplug the power cable. Remove the drip tray. Unscrew the screw fixing the front panel and remove it.
3.
Disconnect the filter and replace it. Flush out the filter (See page 7).
4.
Open water supply. Switch on the water cooler.
When the water cooler is switched on, both indicator lights flash on. The filter light is still on.
5.
Press on the filter reset button. The filter light is on. Release the button, the light is off: the reset is ok.
If the light stays on (for the coolers with serial number begining by 1306 to 1510):
6.
Press on the Reset button until the lights are on
7.
Keep pressing it to reach the temporization mode.
8.
When both lights will flash slowly (the programming mode). Release the reset button.
9.
You have 7 secondes to press on the «cold water» button.
10. The drip tray indicator light will be on indicating a filter life-time of 5000 litres. To have a filter
life-time at 10.000 litres, press on the cold water tap (located at the right of all our key-
boards). The drip tray indicator light will be off & the filter indicator light will be on indica ting a
filter lifte-time of 10000 litres.
11. Press one more time on the reset button, the filter indicator light will flash to valid
your choice. The card reset is done.
12. Replace the front panel, the screw and the drip-tray.
General checking
1.
Control the water circuit.
2.
Verify and control the cooling unit.
3.
Control the water temperature and proceed to an adjustment if necessary.
4.
Verify the érifier les water proofing.
Sparkling water - Choose the right C02 bottle
Use the disposable CO2 cartridge of 600g - Référence : 5144001 - D.75 x H.310 mm

MAINTENANCE

17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents