Problem
Lamp does not
•
Power cord not plugged in.
go on.
•
Fluorescent tube defective.
•
Faulty electronics.
•
Fluorescent tube not prop-
erly seated in the socket.
Compressed air
•
Pneumatic hoses re-
leaking from the
versed.
foot switch.
Foot switch fails
•
No pressure at the com-
to switch on.
pressed air connection.
•
Pneumatic hoses are
kinked.
Foot switch hoses
•
Push-in connection is not
cannot be discon-
released (Fig. 1).
nected from the
unit.
EN
Possible cause
•
•
•
•
•
•
•
•
Corrective action
Plug the power cord into the wall outlet.
Replace the fluorescent tube (refer to Sec. 5.6).
Call for service to replace the electronics, or refer to the spare
parts list.
Refer to Sec. 5.6, "Fluorescent Lamp Installation".
Reverse the connections.
Inspect the compressed air lines and/or the compressor.
Reposition the hoses.
Press the push-in connection ring on the hose side firmly
while pulling on the hoses.