Note the operating instructions. 2.1 Ambient Conditions (in accordance with DIN EN 61010-1) 3.2 Safety Information The Basic master may only be operated: • Indoors; • Always disconnect the unit from the • Up to an altitude of 2,000 m [6,500 ft] above sea compressed air and power sources prior to level;...
3.3 Liability Exclusion 4.4 Filling the Sandblasting Renfert GmbH shall be absolved from all claims Tanks for damages or warranty if: • The product is employed for any purposes Never press the foot switch during filling.
Provided the unit is properly used, Renfert warrants 1. Refer to insert no. 21-9162 for installation. all parts of the Basic master for a period of 3 years. 2. Inspect for abrasive residue. In case of any claims for warranty original dealers‘...
Set of Operating Instructions, with attachment sandblasting unit Spare parts list Power cord The Basic series of Renfert sandblasting units is exclusively recommended by 3M ESPE for use with ROCATEC™. This bonding system is ideal if an 13. Delivery Versions...
15. Troubleshooting Guide Problem Possible cause Corrective action No air and no • Blasting nozzle blocked at • Unscrew the nozzle from the hand-piece and blow it out. abrasive. the hand-piece. • With the nozzle removed, blow out the blasting hose by acti- vating the foot pedal.
Page 11
Problem Possible cause Corrective action Lamp does not • Power cord not plugged in. • Plug the power cord into the wall outlet. go on. • Fluorescent tube defective. • Replace the fluorescent tube (refer to Sec. 5.6). • Faulty electronics. •...