Output (Total Dissolved Solids (TDS) Reduction and Output Production)
Product System Daily Prod� Rate To Pressurized Storage Tank
Prod� Rate without Storage Tank To Atmosphere
Efficiency Rating
Recovery Rating
Influent Challenge Concentration (Mg/L)
Max� Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
Average Percent Removal
1
These systems have been tested under standard laboratory conditions� Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern�
2
Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water
under operating conditions that approximate daily usage�
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as
reverse osmosis treated water when the systems are operated without a storage tank or when the storage tank is bypassed�
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
Product System Daily Prod� Rate To Pressurized Storage Tank
Prod� Rate without Storage Tank To Atmosphere
Efficiency Rating
Recovery Rating
Influent Challenge Concentration (Mg/L)
Max� Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
Average Percent Removal
1
These systems have been tested under standard laboratory conditions� Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern�
2
Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water
under operating conditions that approximate daily usage�
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as
reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed�
Testing Conditions (Complete System)
Temperature:
Pressure:
pH:
Turbidity:
These systems have been tested and shown to operate at their calculated recovery rating under standard laboratory conditions�
These reverse osmosis systems contain a replaceable component critical to the efficiency of the systems� Replacement of
the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure
the same efficiency and contaminant reduction performance�
30
01040605 A 06/21
Tank Size
2
3
Tank Size
2
3
77 F + 2 F
50 psi
7�5 + 0�5
<1 NTU
1
– RO 50
3 gallons
27�8 gpd
28�0 gpd
23�2%
39�2%
737
187
89�6%
92�5%
1
– RO 75
3 gallons
34�1 gpd
34�1 gpd
54�7%
52�8%
737
187
88�5%
90�4%