Culligan Aquasential RO Owner's Manual page 28

Advanced drinking water systems
Hide thumbs Also See for Aquasential RO:
Table of Contents

Advertisement

RO 50 (P/N 01038040)
Aquasential RO Drinking Water Systems with RO 50 have been tested according to CSA B483�1, NSF/ANSI 372, and
NSF/ANSI 58 for the reduction of the substances listed below� The concentration of the indicated substances in water
entering the systems were reduced to a concentration less than or equal to the permissible limit for water leaving the
systems, as specified in NSF/ANSI 58�
These systems are acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite
in combination measured as N and are certified for nitrate/nitrite reduction only for water supplies with a pressure of 280
kPa (40 psig) or greater�
Substance Reduction
Contaminant
Arsenic (Pentavalent)
2
Barium
Cadmium
Hexavalent Chromium
Trivalent Chromium
Copper
Fluoride
Lead
5
Nitrate
Nitrite
Radium 226/228
3
Selenium
Cyst
4
Turbidity
1
While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressure, temperatures and other
substances, which may be found in your water�
2
Thes systems have been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations
of 0�050 mg/L or less� These systems reduce pentavalent arsenic, but may not remove other forms of arsenic� These systems are to be used on water
supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent
arsenic� Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic� Please
see the Arsenic Facts Sheet for further information�
3
Based upon testing methods using Barium as a surrogate� All concentrations in pCi/L pico curie/L�
4
Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium�
5
Units are not certified on water supplies with a pressure less than 40 psi (280 kPa)� A booster pump is strongly recommended�
28
01040605 A 06/21
1
Average Influent
Average Effluent
Concentration mg/L
Concentration mg/L
0�0483
0�0005
9�7
0�1
0�0325
0�0005
0�291
0�0111
0�293
0�0118
2�823
0�0252
8�2
0�2
0�16
0�003
27�0 +/- 10%
10�0
3�0 +/- 10%
1�0
25pCi/L
5pCi/L
0�104
0�0016
>50,000/mL
11 NTU
0�1 NTU
Maximum Effluent
Aquasential RO
Concentration mg/L
Average Percent Reduction
0�0005
99�0%
0�210
99�0%
0�000806
98�4%
0�0162
96�2%
0�0145
96�0%
0�1
99�1%
0�30
97�6%
0�005
98�1%
72�7%
73�9%
5pCi/L
99�0%
0�00205
98�5%
99�99%
0�1 NTU
99�4%
Model: RO 50
Aquasential RO (2yr)
99�0%
99�0%
98�4%
96�2%
96�0%
99�1%
97�6%
98�1%
72�7%
73�9%
99�0%
98�5%
99�99%
99�4%