Through-Wiring - Waldmann TAMETO Instructions For Use Manual

System luminaire
Table of Contents

Advertisement

Available languages

Available languages

Connection
4.3

Through-wiring

Luminaires with through-wiring can be
linkedtooneanotherviathepre-mounted
plug-inconnection"GST18i3S" . T heselumi-
nairesareidentifiedbytheletterDinthe
modelnumber,forexampleSAHQ88D.
Toconnectthefirstluminaire,aconnecting
cableisrecommended,whichcanbefound
intheWaldmannrangeofaccessories.
Formoreinformationontheaccessoriesof
thisluminaire,pleasevisittheWaldmann
homepageat:www.waldmann.com
WARNING
Danger of death due to electric shock.
X Beforeestablishingordisconnect-

ingtheplug-inconnection,discon-
necttheluminairefromthepower
supply.
NOTE: In luminaires with through-wiring
connectedinseries,thetotalcurrentcon-
sumption must not exceed 2 A.The cur-
rentconsumptionofthedifferentluminaire
modelscanbefoundinthefollowingtable:
Luminaire model
SAHQ44xD
SAHQ66xD
SAHQ88xD
SAH124xD
SAH139xD
SAH154xD
Tab.3:Currentconsumptionperluminaire.
X Connecttheluminairestooneanother

using the device plug-in connection
"GST18i3S" .
Current con-
sumption
0.10A
0.15A
0.20A
0.13A
0.21A
0.28A
ENG
31

Advertisement

Table of Contents
loading

Table of Contents