DISASSEMBLY PROCEDURE
16. How to detach and attach the quick joint
Refer to the following steps when detaching and attaching the
quick connection.
(1) Remove the clip. (Photos 16-1 and 16-2)
(2) Separate the connected parts to remove the O-ring. (Photo
16-3)
• Do not reuse the removed O-ring.
• Wipe off if dirt or foreign matters are found on the sealing
surface where the O-ring touches.
(3) Apply grease on the O-ring using a plastic bag, etc. (Photo
16-4)
(4) Attach the O-ring to the male part of quick connection.
(Photo 16-5)
• Keep the O-ring free from dirt or foreign matters.
(5) Connect the male and female parts of the quick connection.
(Photo 16-6)
(6) Attach the clip. (Photo 16-7)
• Ensure to attach the wider diameter of the clip to the fe-
male side. Failure to do so, it may cause water leak at the
connected part. (Photo 16-8) (For the same diameter
quick connection, following this note is not necessary.)
Photo 16-3
Female
Male
Photo 16-6
OCH712C
Photo 16-4
O-ring
Photo 16-7
PHOTOS/ FIGURES
Photo 16-1
Photo 16-2
Photo 16-5
Plastic
bag
O-ring
Photo 16-8
Clip
78
Clip
Clip
Gap