<Summary of settings>
This function shows the current installer/user entered settings.
Abbreviation Explanation
HWtemp
DHW max temperature
HWdrop
DHW temperature drop
HWtime
DHW max operation time
NO HW
DHW mode restriction
HWset
DHW operation mode (Normal/Eco)
Ltemp
Legionella hot water temperature
Lfreq
Legionella operation Frequency
Lstart
Legionella mode start time
Ltime
Legionella max operation time
Lkeep
Duration of max (Legionella) hot
water temperature
Z1 mode
Operation mode
- HER (Heating room temperature)
- HE (Heating flow temperature)
- HCC (Heating compensation curve) FSout
- COR (—)
- CO (Cooling flow temperature)
<Error history>
Error history allows the service engineer to view previous check codes, the unit
address and the date on which they occurred. Up to 16 check codes can be
stored in the history and the most recent Error event is displayed at the top of the
list.
1. From the service menu, select Error history
2. Press CONFIRM.
Please see "10-4. Self diagnosis and action" for check codes diagnosis and
actions.
To delete an Error history item;
1. From Error history screen, press F4 button (Rubbish bin icon)
2. Then press F3 button (Yes).
<Password protection>
Password protection is available to prevent unauthorised access to the service
menu by untrained persons.
1. From the service menu, use F1 and F2 buttons to scroll through list until
Password protection is highlighted.
2. Press CONFIRM.
3. When password input screen is displayed, use buttons F1 and F2 to move left
and right between the 4 digits, F3 to lower the selected digit by 1, and F4 to in-
crease the selected digit by 1.
4. When you have input your password, press CONFIRM.
5. The password verify screen is displayed.
6. To verify your new password, press button F3.
7. Your password is now set and the completion screen is displayed.
OCH712C
Abbreviation Explanation
Z2 mode
Operation mode
- HER (Heating room temperature)
- HE (Heating flow temperature)
- HCC (Heating compensation curve)
- COR (—)
- CO (Cooling flow temperature)
Hroom 1
Heating target room temperature
Hroom 2
Heating target room temperature
Hflow 1
Heating target flow temperature
Hflow 2
Heating target flow temperature
Croom 1
Cooling target room temperature
Croom 2
Cooling target room temperature
Cflow 1
Cooling target flow temperature
Cflow 2
Cooling target flow temperature
FSflow
Freeze stat function flow temperature
Freeze stat function ambient temperature