4. Quick start and feature introduction
Get started quickly

4.1 Hardware preparation

This test requires the following devices to be prepared:
Before testing, plug in
(At this point the PWR light goes on and theWORK
(The computer needs to install USB re-serial driver first, download the parameter configuration software in advance, you
can go to
our official website
4.2 Network transmission mode
Open the parameter configuration software
1、Select the appropriate port number
2、Select Baud Rate 115200(factory default).
3、Select Check, Data, Stop None,8,1(factory default).
4、Open the serial port
5、Click to enter configuration mode
6、Modify the server address or IP,port, connection type (in this case, the E.U.S. test server, you can fill in the
corresponding server information).
7、Click to save all parameters
8、Click on the module restart (at which point WORK,NET, etc. flashes and turns off to indicate a successful restart).