Ocu dp access module
Hide thumbs Also See for Total Access 850:

Advertisement

OCU DP Pair Locator for Total Access 750/850/1500
TA 1500
T/R
T1/R1
TA 1500
Slot
RX (P1)
TX (P2)
Slot
1
26/1
26/1
13
2
27/2
27/2
14
3
28/3
28/3
15
4
29/4
29/4
16
5
30/5
30/5
17
6
31/6
31/6
18
7
32/7
32/7
19
8
33/8
33/8
20
9
34/9
34/9
21
10
35/10
35/10
22
11
36/11
36/11
23
12
37/12
37/12
24
PROVISIONING
The Total Access 750/850/1500 OCU DP supports two types of provisioning modes, local and remote.
Local provisioning results in the module operating as defined by the on-board switches. Remote
provisioning results in the module operating as defined by the Bank Controller Unit (BCU) or System
Controller Unit (SCU) menu settings (on-board switches are ignored). The operational mode is
indicated by the
LED and can be changed by depressing the
REM
Remote Provisioning
The craft interfaces on the BCU or SCU are used to change default options and obtain access module
status through menu screens. To access the menu screens, connect a VT100 terminal or a computer
running a terminal emulation program to the front panel craft interface ADMIN port using a standard
male-to-female RS-232 DB-9 cable.
Windows HyperTerminal can be used as a VT100 terminal emulation program. Open HyperTerminal
by selecting
Programs/Accessories/HyperTerminal
additional information.
To traverse through the menus, select the desired entry and press
menu press the
(escape) key. The figure on the right illustrates the OCU DP menu tree.
E
SC
TESTING
The OCU DP is equipped with logic level bantam test access jacks that permit testing in both directions
using a portable test set. Latching and alternating OCU and CSU loopback sequences are supported.
Alternating loopbacks do not operate when the 64 kbps data rate is selected. Choose NEAR to test
toward the 4-wire customer loop direction; choose FAR to test toward the T-carrier.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty.
Total Access 750/850/1500 OCU DP Access Module
T/R
T1/R1
TA 750/
T/R
RX (P1)
TX (P2)
850 Slot
RX
38/13
38/13
1
26/1
39/14
39/14
2
30/5
40/15
40/15
3
34/9
41/16
41/16
4
38/13
42/17
42/17
5
42/17
43/18
43/18
6
46/21
44/19
44/19
45/20
45/20
46/21
46/21
47/22
47/22
48/23
48/23
49/24
49/24
switch on the front panel.
AP
. Refer to the Help section of HyperTerminal for
. To work backward in the
E
NTER
In the FAR direction, an OCU loopback sequence will loop the unit directly across the carrier system.
In the NEAR direction, an OCU loopback sequence will loop the unit directly connected to the portable
test set.
T1/R1
NOTE: If 64 kbps is selected, unit will only respond to latching loopback sequences. Alternating
TX
sequences are not valid at this rate.
27/2
31/6
COMPLIANCE
35/10
The OCU DP is NRTL listed to the applicable UL standards. The OCU DP is to be installed in a
39/14
restricted access location and in a Type "B" or "E" enclosure only.
43/18
The Total Access 750/850/1500 Chassis frame ground terminal must be connected to an earth ground
47/22
to ensure the front panel of the OCU DP is properly grounded via the backplane connector.
Code
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by ADTRAN could void the user's authority to
operate this equipment.
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
Input
Output
C
C
X
A
Unit Name
1. Configuration
CLEI Code
Part Number
Software Revision
1. Data Rate
2. Provisioning
2. Secondary Channel
3. Latching Loopback
4. Quality Monitor Disconnect
5. Error Correction
6. Zero Code Suppression
7. Hardware A/B Signaling
ABS Code to Network
3. Status
Loop Sealing Current
Loop Receive Signal
Quality Monitor Decision
Loop Circuit
Loopback
www.adtran.com
61180005L1-22C
1. 64 kpbs
2. 56 kbps
3. 19.2 kbps
4. 9.6 kbps
5. 4.8 kbps
6. 2.4 kbps
7. Sw56
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled