BWT  bestaqua 22 HQ Fitting And Operating Instructions
Hide thumbs Also See for BWT bestaqua 22 HQ:

Advertisement

Quick Links

BWT bestaqua 22 HQ
BWT bestaqua 24 HQ
BWT bestaqua 26 HQ
Fitting and operating instructions
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BWT bestaqua 22 HQ and is the answer not in the manual?

Questions and answers

Summary of Contents for BWT BWT bestaqua 22 HQ

  • Page 1 BWT bestaqua 22 HQ BWT bestaqua 24 HQ BWT bestaqua 26 HQ Fitting and operating instructions...
  • Page 2 Thank you very much for the con- fidence that you have shown in us Table of contents Page 3 by purchasing a BWT appliance.
  • Page 3: Table Of Contents

    Table of contents Chapter 1: Introduction & safety ........................4 1.1 Abbreviations and subject index ...................... 4 1.2 Scope of delivery .......................... 5 1.3 Manufacturer ..........................5 1.4 General comments ......................... 5 1.4.1 Reading of the manual (IOM) ....................5 1.4.2 Warranty provisions and disclaimer ..................
  • Page 4: Chapter 1: Introduction & Safety

    6.1 Technical data BWT bestaqua 22,24,26 HQ .................. 24 6.2 Diagrams with characteristic curves ....................25 Chapter 7: Documentation .......................... 26 7.1 Form for set values of BWT bestaqua 22,24,26 HQ ................ 26 EC declaration of conformity ........................27 1.1 Abbreviations and subject index Softening: Conductivity, electrical conductivity:...
  • Page 5: Scope Of Delivery

    Permeate connection ¾“ male thread with 3/8“ female 10 Concentrate connection Ø 8mm JG-connection 11 Service cap for security valve of the pump Fig. 1: BWT bestaqua 22,24,26 HQ - Front view of the device Optionally available, Item no. 824047: 12 External contacts (INPUT/OUTPUT), 3-pin, M8...
  • Page 6: Warranty Provisions And Disclaimer

    Note: Additional information for the operator. prior art and our long term experiences. 1.5 Operation and safety precaution advices BWT excludes any responsibility for damages and The following chapter provides an overview of all important for consequential loss due to: operation and safety precaution advices to enable safe operation •...
  • Page 7: Prohibited Mode Of Operation

    The user has to be trained by a BWT organisation or other • Unauthorized reconstruction work as well as technical authorised person to operate the RO device.
  • Page 8: Preconditions For The Installation

    • It is recommended to install a shut-off valve at the inlet side of Further pre-treatment is to be determined by the BWT service the unit, so that the feed water supply may be interrupted for in dependence on the local feed water quality.
  • Page 9 • Please open the valve for the feed water supply. • The BWT bestaqua 22,24,26 HQ device line is to be installed • Connect the RO unit to the power supply (230V/50 Hz).
  • Page 10: Chapter 3: Operation And Programming Of The Software

    3.1 Quick operation guide The BWT bestaqua 22,24,26 HQ devices could be controlled and parameterised with the control unit. The display of the RO unit shows after the starting phase all currently measured operating values. 3.2 Function keys and display elements READY ;...
  • Page 11: Switching The Device On And Off

    3.3 Switching the device ON and OFF Interrupting the production: Switching the device ON: Brief pressing of the [ON/OFF] button, the device swit- ches to “PAUSE“. The device restarts after pressing the To activate the device, it has be correctly connected to button and is immediately available for operation.
  • Page 12: Option: External I/O Installation Kit

    FLUSH / flushing process step after stop: EXT. PAUSE / (remote pause in OPTION): In the operating status “flush/FLUSH“ start the flushing procedure When the RO unit displays “remote pause/EXT. PAUSE“ the RO of the RO membranes with permeate run after each stop. The units unit is interlocked by the external control.
  • Page 13: Device Settings/Visualisation

    “Form for set values BACK Quit menu and return to selection menu of BWT bestaqua 22,24,26 HQ“ (see Part 7.1). Fig. 11: Display of the activated “SETUP“ menu. Document the parameters after you have set all of Perform the general settings of the “SETUP“...
  • Page 14 AUTO RINSE DATE / TIME Fig. 13 SERVICE CONDUCTIVITY / TDS STOP DELAY OPERATION MODE SETUP LANGUAGE EXIT BACK DATE / TIME DATE / TIME DATE / TIME CONDUCTIVITY / TDS CONDUCTIVITY / TDS CONDUCTIVITY / TDS OPERATION MODE OPERATION MODE OPERATION MODE LANGUAGE LANGUAGE...
  • Page 15 Fig. 14 DATE / TIME CONDUCTIVITY / TDS Fig. 14 ... to call up: OPERATING MODE Fig. 12 OPERATION MODE LANGUAGE BACK PASSWORD: SET METER SET METER SET METER SET LIMIT SET LIMIT SET LIMIT BACK BACK BACK PASSWORD PASSWORD *EC (µS) _ _ _ _ _ _ _ _ _ _ _ _...
  • Page 16 DATE / TIME to call up the “LANGUAGE“ menu point, please refer to Fig. 12 CONDUCTIVITY / TDS OPERATION MODE Fig. 13 LANGUAGE PASSWORD: BACK OPERATING MODE OPERATING MODE OPERATING MODE START PRESSURE START PRESSURE START PRESSURE STOP PRESSURE STOP PRESSURE STOP PRESSURE BACK BACK...
  • Page 17: Menu: Service (Maintenance)

    SERVICE parameter: Note: The menu “SERVICE INTERVAL“ is secured by a • Settings of password. Please contact the BWT service, in case of a change of the system settings. a Press the arrow keys to call up the menu screen.
  • Page 18 AUTO RINSE SERVICE FLUSH TIME STOP DELAY EXIT SERVICE INTERVAL SERVICE RESET BACK PASSWORD _ _ _ _ _ _ PASSWORD: Password input: SERVICE DAY SERVICE DAY SERVICE DAY SERVICE DAY SERVICE PRE-FILTER SERVICE PRE-FILTER SERVICE PRE-FILTER SERVICE PRE-FILTER SERVICE POST-FILTER SERVICE POST-FILTER SERVICE POST-FILTER SERVICE POST-FILTER...
  • Page 19: Menu: Auto Rinse (Automatic Rinsing)

    3.8.3 Menu: AUTO RINSE RINSE SERVICE D Press the arrow keys to call up the detailed overview screen. SETUP “PAUSE“ a Select the detail item and confirm with [✓] button to STOP DELAY shift into the programming menu. EXIT PERM 3.2 bar _ _ _ PUMP _ _ _...
  • Page 20: Chapter 4: Fault Finding

    4.1 Overview of the Status- and Alarm LED Description of the unit status: Status and alarm: LED colour / indication: Ready for new permeate demand ready/READY green / flashing  working/WORKING (production) green / lights up Unit produces permeate (pure water) ●...
  • Page 21 4.2 Trouble shooting guide Please observe: If your reverse osmosis is not performing as it should, please run through the alarm messages below. In the event of a fault, repair work may only be carried out by an expert (SERVICE technician). Alarm / malfunction list: Possible reasons: Acknowledgement:...
  • Page 22: Chapter 5: Maintenance And Service

    May 2007. Therefore, it meets the requirements of Article 3, Section 3, and is consequently manufactured and assembled in accordance with applicable good engineering practice. The BWT bestaqua 22,24,26 HQ devices do not receive a CE mark in accordance with Article 15 of Directive 97/23/EC. However, the attached EC declaration of incorporation is applicable.
  • Page 23: Cleaning

    ✔ 7. Measurement of the input water hardness °dH (with hardness test set): 5.5 Disposal Procedure: The BWT bestaqua 22,24,26 HQ devices consists of various materials which need to be disposed of properly. ✔ Please order the manufacturer customer service by your contractor for and environmentally compliant disposal.
  • Page 24 The RO unit is factory preset with a WCF by approx. 40%. With an appropriate water treatment it is ready for the use for higher permeate yields with the optional “high-efficiency WCF kit“. (Item no. 824039 for BWT bestaqua 22/24 HQ, Item no. 824040 for BWT bestaqua 26 HQ) BWT bestaqua...
  • Page 25 7.1 Form for set values of BWT bestaqua 22,24,26 HQ Note: Please copy a blank page of these form. Then fill out the following table at every initial and further installation and archive the data-sheet. Date of installation: ../ ../ ..
  • Page 26 6.2 Diagrams with characteristic curves Power depending on the pump pressure 10.0 Pump pressure [bar] Permeate temperature dependence Factor Temperature [°C]...
  • Page 27 • DVGW Guideline for drinking water hygiene, scope of law in in Germany Manufacturer: BWT water + more GmbH, Walter-Simmer-Straße 4, A-5310 Mondsee, Phone: + 43 (0) 6232 5011 - 0 Mondsee, February 2015 Place, date / Ort, Datum / Lieu, date Dr.
  • Page 28 BWT – The Company Austria France Spain/Portugal BWT water + more GmbH BWT France SAS, BWT water+more Iberica S.L. Walter-Simmer-Straße 4 Silici, 71 - 73 Division water+more A-5310 Mondsee E-08940 Cornella del Llobregat 103 rue Charles Michels Phone: +43 / (0)6232 / 5011-0...

This manual is also suitable for:

Bwt bestaqua 24 hqBwt bestaqua 26 hq

Table of Contents