Control and monitoring from your mobile phone

Advertisement

The 4G Auto Dialler has two relay outputs which can be used to switch on external devices
such as lighting, sirens etc...
Relay 1
is independent and can be activated by SMS message
Relay 2
is independent and can be activated by SMS message
Relay 2 can be used to turn on a siren or lighting etc , for approximately 17 seconds
automatically when an input or alarm have been triggered. Please be aware of any conflicts
this may cause if you are already using relay 2 as an independently activated relay.
To turn this function on please send the SMS
#AUTO=ON#
this will turn the AUTO function on for relay 2 only
#AUTO=OFF#
this will turn the AUTO function off for relay 2 only (default setting is off)
By texting the unit you can turn relay 1 and 2 ON or OFF individually. Below, are examples on
how to do this.
#REL1=ON#
This will turn on relay 1
#REL1=OFF#
This will turn off relay 1
#REL2=ON#
This will turn on relay 2
#REL2=OFF#
This will turn off relay 2
After each operation the unit will reply with the status report REL 1 ON/OFF
It is possible to pulse relay 1 & 2 for a period of 17 seconds. You will need to send the text
message as follows.
#PUL=REL1#
- This will pulse relay 1 for 17 seconds
#PUL=REL2#
- This will pulse relay 2 for 17 seconds
The unit will reply back with REL1 or REL2 PULSE
.
How to Use the Relay Outputs
Auto Relay Trigger (Relay 2)
Activation by SMS Text Message