Notes
1. You lose vacuum immediately if you disconnect the vacuum hose!
2. Vacuum hose connection.
a. Disconnect vacuum hose.
b. Connect vacuum hose.
c. If there is a leak, the VacuMount will not hold or the vacuum pump will always
pump.
3. Suction cups can be changed easily.
4. The Suction cups are designed in such a way that they still get vacuum on certain con-
vex and concave surfaces. However, use a suction cup with a different size or form, if the
surface is to much curved.
5. Normally, the suction cup is attached tightly and goes off easily. Nevertheless, the
suction cup should be regularly removed after 12-24 hours at the latest. Please clean and
maintain the device regularly using a special rubber-care product. This measure extends
the life of the suction cup and prevents it from sticking to the surface.
6. Clean surface after use to remove possible prints.
7. Cut vacuum hose right after the bend if the hose is cracked. You can repeat this
procedure until the vacuum hose becomes to short.
8. IDEA VISION recommends tubes with a size of 33mm (weight!).