Lennox LI009CI-160T432 Service Manual page 103

Hide thumbs Also See for LI009CI-160T432:
Table of Contents

Advertisement

Step
4. Remove axial flow blade
Remove the nut fixing axial flow blade and then
remove the blade.
5.Remove electric box assy
a
Remove the grounding wire screw on the
e l e c t r i c b o x a s s y a n d t h e n r e m o v e t h e
grounding wire. (See fig 1)
Disconnect the wiring terminals of reactor,
b
compressor, high and low pressure switch,
compressor overload protector, temperature
sensor, outdoor fan motor and 4-way valve. (See
fig 2)
N o t e : k e e p p r e s s i n g t h e c i r c l i p w h e n
disconnecting the wiring terminal of reactor;
keep pressing the retainer when disconnecting
other wiring terminals.
c
Remove the wire inside the wiring groove.
100
Procedure
nut
axial flow blade
(2)
high and low
pressure switch
Terminal of
compressor
overload
protection
Terminal of
temperature
sensor
circlip
PFC induction
wire
grounding wire
Terminal of
4-way valve
Terminal of
outdoor fan
Terminal of
compressor wire
Installation and Maintenance
Service Manual
retainer

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents