Olmo OSH-T24HRK3 Owner's Manual page 8

Cassette air conditioner
Table of Contents

Advertisement

INDOOR UNIT INSTALLATION
SHAPE OF INDOOR UNIT
a.
distance between
b.height of panel ceiling sponge
c.distance between hook and indoor unit top
d.distance between ceiling and indoor unit top
e.height of indoor unit;
A.dimension of panel
B.dimension of ceiling cut-out
C.dimension of indoor unit.
BODY DIMENSION:580 255 580
Please select the space to install indoor unit according to the dimension show
above,then install correctly,and have enough space for maintenance.
Select installation location considering piping and wiring connection after the Indoor Unit has
been hanged. Then decide the piping wiring leading direction.
Be sure to lead the refrigerant pipes, drain pipes and connection wires out to its connection
location before hanging the unit if the opening on the ceiling has been decided.
Confirm sizes of the indoor unit and ceiling opening with the attached installation paper
pattern. (Please fix the paper pattern below the body with M5X16 screws (4).
hook and ceiling
Ceiling
Drainage pipe
Ceiling
B=875~910
D4=780
BODY DIMENSION:830 230 830
BODY DIMENSION:830 310 830
6
Refrigerant pipe
mm
mm
D2=760
mm
C=835
mm
A=950
mm

Advertisement

Table of Contents
loading