8 Technical data
8.3

Performance diagrams

8.3.1

EKHWD / EKHWC

Maximal available hot water volume at 40°C is shown as a function
of the draw-off rate in
"  
[ 4   30] for 10°C cold water entry temperature and 60°C
reheating" 
storage tank temperature at draw-off start and reheating with 20 kW.
  8‒2 Hot water performance with reheating
S#Q
EKHWC500Bx
S#H
EKHWCH500Bx
S#I
EKHWCB500Bx
S#J
EKHWCH300Bx
S#K
EKHWCH500PBx
S#L
EKHWCB500PBx
S#M
EKHWCH300PBx
S#O
EKHWDH500Bx
S#P
EKHWDB500Bx
Z/ L/min
Draw-off rate in litres per minute
V
/L
Maximum draw-off capacity in litres
Zmax
INFORMATION
Draw-off rates >36 l/min can, in certain rare circumstances,
lead to noises in the domestic water heat exchanger of the
hot water storage tank.
  8‒3 Pressure drop characteristic for the heat exchanger
a
Drinking water heat exchanger (EKHWDH500Bx,
EKHWDB500Bx, EKHWC500Bx, EKHWCH500Bx,
EKHWCH500PBx, EKHWCB500Bx, EKHWCB500PBx)
b
Drinking water heat exchanger (EKHWCH300Bx,
EKHWCH300PBx)
c
Storage tank charging heat exchanger 1 or 2
(EKHWDH500Bx, EKHWDB500Bx, EKHWCH500Bx,
EKHWCH500PBx, EKHWCB500Bx, EKHWCB500PBx)
d
Storage tank charging heat exchanger 1
(EKHWCH300Bx, EKHWCH300PBx)
e
Heating support heat exchanger (EKHWCH500Bx,
EKHWCH500PBx, EKHWCB500Bx, EKHWCB500PBx)
Δp/mbar
Pressure drop in millibar
m/ L/h
Flow rate in litres per hour
m/ L/min
Flow rate in litres per minute
Installation and operating manual
30
8‒2 Hot water performance with
8.3.2

EKHWP

Maximal available hot water volume at 40°C is shown as a function
of the draw-off rate in
"   8‒4 Hot water performance without
[ 4   30] for 10°C cold water entry temperature and 60°C
reheating" 
storage tank temperature at draw-off start without reheating.
  8‒4 Hot water performance without reheating
S#A
EKHWP54419Bx
S#B
EKHWP500Bx
S#D
EKHWP300Bx
S#F
EKHWP500PBx
S#G
EKHWP300PBx
Z/ L/min
Draw-off rate in litres per minute
V
/L
Maximum draw-off capacity in litres
Zmax
INFORMATION
Draw-off rates >36 l/min can, in certain rare circumstances,
lead to noises in the domestic water heat exchanger of the
hot water storage tank.
  8‒5 Pressure drop characteristic for the heat exchanger
a
Drinking water heat exchanger (EKHWP54419Bx,
EKHWP500Bx, EKHWP500PBx)
b
Drinking water heat exchanger (EKHWP300Bx,
EKHWP300PBx)
c
Storage tank charging heat exchanger 1 (EKHWP500Bx,
EKHWP500PBx)
d
Storage tank charging heat exchanger 1 (EKHWP300Bx,
EKHWP300PBx)
e
Storage tank charging heat exchanger 1
(EKHWP54419Bx)
f
Heating support heat exchanger (EKHWP54419Bx,
EKHWP500Bx, EKHWP500PBx)
Δp/mbar
Pressure drop in millibar
m/ L/h
Flow rate in litres per hour
m/ L/min
Flow rate in litres per minute