Solution For Oil Or Gas Condensing Boilers; Solution For Sanitary Side Connection - Daikin Altherma ST EKHWCH300B Installation And Operating Manual

Hot water storage tank
Hide thumbs Also See for Altherma ST EKHWCH300B:
Table of Contents

Advertisement

6 Hydraulic
6.1.3

Solution for oil or gas condensing boilers

  6‒3 Standard connection schematic with condensing boiler and pressurised solar system
6.1.4

Solution for sanitary side connection

Observe legal regulations according to
connection" [ 4  5]
side
  6‒4 Standard connection schematic for sanitary side
  6‒1 Short names in hydraulic drawings
Short name
a
Cold water distribution network
b
Hot water distribution network
c
Heating flow
d
Heating return flow
e
Non return valve (circulation brakes e.g. SKB)
f
Solar circuit
g
Circulation (optional, if permitted according to local
legislation)
(1)
The displayed system schematic do not claim to be complete and do not replace careful system planning.
Legend see
"
  6‒1 Short names in hydraulic
Installation and operating manual
22
"1.2.6  Heating and sanitary
Meaning
drawings" [ 4  22].
(1)
Short name
h
Non return valve
i
Pressure reducer
k
Manometer
l
Shut-off valve
3UV1
3-way switch valve (DHW)
3UV2
3-way switch valve (cooling)
3UV3
3-way switch valve (heating support)
cbo
Oil or gas condensing boiler (Daikin Altherma C Oil
shown as example)
BSK
Burner blockage contact in EKSRPS4A
BV
Overflow valve
CW
Cold water
CWD
Cold water distribution
DHW
Domestic hot water
DSR1/2
Solar differential temperature control unit
EHS157068 Mixer circuit control unit
EKBUxC
Electric immersion heater
EKSRDS2A Pressure station
EKSRPS4A Solar control and pump unit
EP3
Hot water module E-Pac LT (heating/cooling)
FLG
FlowGuard - solar regulating valve
FLS
FlowSensor - solar flow and flow temperature
measurement
H
, H
... H
Heating circuits
1
2
m
Daikin Altherma ST (Hot water storage tank)
Meaning
EKHW(D/C/P)(300/500)(P)B
008.1633099_00 – 06/2020

Advertisement

Table of Contents
loading