Contents Installer Instructions Thank you for choosing ESi Controls. 1 Technical Specification Programmable Room Thermostat All our products are tested in the UK so we are 2 Installation Instructions confident this product will reach you in perfect Installation Safety Instructions condition and give you many years of service.
1. Technical Specification 2. Installation Installation Safety Instructions Programmable Room Thermostat The unit must be installed by a suitably qualified person in Programming 7 Day, 5/2 Day & 24Hr accordance with the latest IEE Wiring Regulations. 2 x 1.5V Lithium batteries Power supply (type: AA size) Isolate mains supply before commencing installation.
Warning Notices WARNING: Always isolate the AC mains supply before installing. This product must be fitted by a competent person, and installation must comply with the guidance provided in the current editions of BS767 (IEE wiring 1.5m regulations) and part “P” of the building regulations. Wiring Diagram Fitting the Programmable Room Thermostat The ideal position to locate the Programmable Room...
3. Technical Settings 6. Insert the 2 x AA batteries provided in the battery compartment on the front of the thermostat, underneath the fascia. The Programmable Room Thermostat is now installed and will automatically Setting TPI, Delayed or Optimum Start start to control the room temperature according to 1.
the Next Menu Parameter Settings button and the technical settings menu will be displayed. Release all buttons. Parameter Feature Comment 2. Press the Next button until you get to the SWING Low Load control Use + or – to disable (OFF) / enable (ON).
1: Reminds the user when the annual service is due by constantly and the system ON time will be controlled by displaying SER in the screen 30 days before due date the SER SET. 2: Reminds the user when the annual service is due by N.B.
Page 9
Partial Lockout 3 WARNING: Interference with sealed parts renders the guarantee void. This mode allows the installer to set the Maximum temperature Setpoint (factory default 21°c), and locks In the interests of continuous product improvement we reserve all keys/slider except, to change the time and date, off the right to alter designs, specifications and materials without (frost protection) and allow temporary manual override prior notice and cannot accept liability for errors.
Page 10
We are continuously developing our products to bring you the very latest in energy saving technology and simplicity. However, should you have any questions setting up your controls please email us at tech@esicontrols.co.uk or for technical queries call us on our dedicated technical helpline 01280 816868.
Need help?
Do you have a question about the ESRTP4+ and is the answer not in the manual?
Questions and answers