6-16. Trigger Schedule Select

SCHD
1
OM-254915 Page 48
.
A complete Parts List is available at www.MillerWelds.com
1
Lit Indicator
The Trigger Schedule Select is an
advanced feature that allows chan-
ging between two sets of weld para-
meters. To activate the Trigger Se-
lect feature, simultaneously de-
press both the blue set-up and arc
control buttons. Rotate the left con-
trol knob clockwise to select
"SCHD". Rotate the right control
knob to select 'TRIG". Now push
the Setup button or pull the trigger to
return to the main menu.
Now set the second weld paramet-
er or "Schedule B". Quickly pull and
release (pop) the gun trigger to illu-
minate the "Schedule B" indicator
located on the top left side of the
front panel. Since the gun, wire type
and diameter is already known, it is
only necessary to select a welding
process and the settings. For MIG,
select volts and wirefeed speed.
For Synergic MIG, select wirefeed
speed and voltage. For Synergic
Pulse MIG, select Arc Length and
wirefeed speed.
For "Schedule B", the wirefeed
speed is set using the right control
knob on the power source, not the
gun.
Now that "Schedule B" parameters
are set, simply "tap" the gun trigger
to toggle between the two pro-
grams.
Ref. 242 929-C