Operation During A Power Outage; Cleaning And Care; Error Indications; Specifications - Toto Neorest Series II TL993SE Owner's Manual

Lavatory faucet
Hide thumbs Also See for Neorest Series II TL993SE:
Table of Contents

Advertisement

Available languages

Available languages

C
Nettoyage de la Commande
NOTE: Close the two stop valves (hot/cold) before maintenance.
Open the two valves after completing the maintenance.
NOTA: Cierre las dos válvulas de cierre (caliente/frío) antes del
mantenimiento. Abra las dos válvulas después de comple-
tar el mantenimiento.
REMARQUE: Fermez les deux robinets d'arrêt (chaud/froid) avant
l'entretien. Ouvrez les robinets d'arrêt une fois
l'entretien terminé.
1) Remove the cover and pull out the filter.
1) Retire la cubierta y jale el filtro hacia afuera.
1) Retirez le couvercle et extrayez le filtre.
2) Clean the filter with a brush.
2) Limpie el filtro con un cepillo.
2) Nettoyez le filtre à l'aide d'une
brosse.
Cleaning the Filter in the Spout
D
Limpiando el Filtro en el Surtidor
Entretien du Filtre du Robinet
1) Remove the filter with a fine-tipped tool.
1) Retire el filtro con una herramienta con punta fina.
1) Retirez le filtre à l'aide d'un outil muni d'une pointe
aplatie.
2) Clean the filter with a brush.
2) Limpie el filtro con un cepillo.
2) Nettoyage le filtre à l'aide d'une brosse.
3) Put the filter back. The filter is curve-shaped, so please
make sure it is placed back at the right angle.
3) Ponga el filtro de vuelta. El filtro tiene forma de curva,
asegúrese que esté colocado de vuelta en el ángulo
correcto.
3) Remettez le filtre en place. Le filtre est incurvé, pour
cette raison faites attention à le remetrre dans le bon
angle.
Cleaning the Filter
Limpiando el Filtro
3) Put the filter back and
close the cover.
3) Ponga el filtro de vuelta
y cierre la cubierta.
3) Replacez le filtre et re-
fermez le couvercle.
6

OPERATION DURING A POWER OUTAGE

E
Operation of the Manual Operating Valve
The handle cannot be operated during a power outage. Use the manual operating valve instead.
1) To start the water:
Turn the valve
clockwise.

CLEANING AND CARE

Clean the parts regularly to prevent the accumulation of dirt and lime-scale.
For daily cleaning, use a neutral cleaner.
Acids are necessary ingredients of cleaning materials for removing lime. However, please pay attention to the follow-
ing points when cleaning fittings:
• Only use cleaning materials which are explicitly recommended for this type of application.
• Never use cleaning materials which contain hydrochloric, formic or acetic acid, as they may cause considerable
damage.
• Do not use phosphoric acid as it can also cause damage.
• Never use cleaning materials or appliances with an abrasive effect, such as cleaning powders, sponges or microfi-
ber cloths.
Please follow the cleaning material manufacturer's instructions. In addition, pay attention to the following points:
• When using spray cleaners, spray first onto a soft cloth or sponge. Never spray directly onto the fittings, as drops
could enter openings and gaps, which can then cause damage.
• After cleaning, rinse thoroughly with clean water to remove any cleaner residue.
Components with damaged surfaces must be exchanged, otherwise this can cause an injury. Damage caused by
improper treatment will not be covered by our warranty.

ERROR INDICATIONS

Check the flashing light pattern of the handle and refer to the following table:
Flashing
Problem
Solution
Pattern
Red flashing
Hot water
Wait for a moment and then press the handle again.
(2 times per
temperature is
• If the hot water temperature exceeds 122°F, the water will stop automatically.
second)
extremely high
• Operation is not possible until the water temperature in the controller is lowered.
Pink flashing
Malfunction of
Disconnect the main plug and then reconnect it.
the controller.
If the flashing continues, request a repair.
Blue flashing

SPECIFICATIONS

• Operating pressure range:
- Recommended:
• Hot water supply temperature:
(Refer to your local code for the maximum allowed temperature)
• Cold water supply temperature:
• Discharge water temperature:
• Flow rate:
(Refer to the "How To Use" section in this manual)
• Supply voltage:
• Waterproof specifications:
• Water inlet:
2) To stop the water:
Turn the valve
counter-clockwise.
Min: 10 psi (0.07 MPa) flow pressure
Max: 80 psi (0.55 MPa) static pressure
30 psi-44 psi (0.2-0.3 MPa)
120°F-180°F (49°C-82°C)
39°F-80°F (4°C-27°C)
93°F-112°F (34°C-44°C)
1.3 gpm (5 lpm) or 2.0 (7.6 lpm)
AC 100-240 VAC (50/60 Hz)
IPX3 (handle)
IPX3 (controller)
1/2" NPSM
7

Advertisement

Table of Contents
loading

Table of Contents