Download Print this page

Specifications; Installation Procedure; Operation - Toto TLP01701J Installation Manual

Auto faucet

Advertisement

CN
1
2
3
4
5
6
7
8
9
GB

Specifications

Power supply
Sensor detection range
Water supply pressure
Water supply connection
Ambient temperature
Flow rate

Installation Procedure

1
Mount the bracket on the wall.
2
Remove the controller cover.
3
Connect the controller to the water
inlet braket.
Connect the flexible hose to the
bracket inlet.
4
Fasten the spout.
5
Cut the hose if necessary.

Operation

Normal mode
• (Water comes out when you hold out your hand.)
• (Water stops when you withdraw your hand.)
• The mode shown below can be engaged by changing the DIP switches of the controller.
Continuous water spouting mode
If you trigger sensor detection for 3 sec. or longer, water spouts for 1 min. at a maximum.
If you trigger sensor detection again, water stops spouting.
Cleaning mode
If you hold your hand over the sensor for 10 sec., the indication lamp turns off
for 5 sec. If you leave your hand over the sensor while the indication lamp is
off, no water is discharged for a maximum of 1 min.
If you trigger sensor detection again, water spouts.
Cold water priority mode
This function prevents the wasteful use of hot water. Even after the hot water
is used, this function returns to the "Cold water mode".
Equipment protection wash
If no one uses the product for 24 hours since it was used the last time, water
spouts automatically for 5 sec.
-8-
AC 100 240V
Sensor is self-adjusting (130~200mm)
minimum required water pressure 0.05MPa (Flowing)
maximum water pressure 1.0MPa
6
Connect the hose.
7
Insert the sensor connector
(white×2) till it stops with a click.
It is no problem to insert it in either
right or left one.
Insert the (white,orange) connector
of LED Unit till it stops with a click.
8
Attach the controller cover.
9
Insert the power plug.
G3/8
0~40°C
3L/min

Advertisement

loading

This manual is also suitable for:

Tlp01702b