Calibration Steps; Specifications - HOBBYEAGLE A3 PRO V2 User Manual

Table of Contents

Advertisement

Calibration STEPS

A3 Pro V2 uses a quick approach for accelerometer calibration, there are only 2 steps corresponding to
both sides of Z axis of the unit required to be calibrated. Each step will take about 2 seconds. While
calibrating, the LED will flash Blue several seconds and then light up solid in Blue. Do not move the gyro
until the calibration is done.
Step 1
Put the gyro flat and face up on the table and make it parallel to
the desktop. short press the button, do not move the gyro while the LED is
flashing Blue quickly.
Step 2
Put the gyro flat and face down on the table and make it parallel
to the desktop, short press the button, do not move the gyro while the LED
is flashing Blue quickly.
Finish
After you have finished the 2 steps above, the LED will flash Violet
once which indicates that the calibration is complete, after a successful
calibration the gyro will start the initialization automatically.

SPECIFICATIONS

Main Controller:
Sensors:
Gyroscope Scale Range:
Accelerometer Scale Range:
PWM:
Input Voltage:
Operating Temperature:
Size:
Weight:
WWW.HOBBYEAGLE.COM
32-bit MCU
High-precision 3-axis gyroscope and 3-axis accelerometer
±2000dps
±4g
920uS to 2120uS with 1520uS center length, 50Hz to 333Hz
4.8V to 8.4V
-10℃ to 50℃
43×27×14mm
10g (excluding wires)
15 / 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents