Operating Features - IDEAL 61-737 Operation And Safety Manual

400-amp ac clamp meter
Table of Contents

Advertisement

Available languages

Available languages

Operating Features

High Voltage Warning (HI-V)
The meter LED remains RED and the beep lasts for 1 second and then goes silent
when voltages in excess of 30V are measured.
NOTE: This feature does not work in the Ohm, capacitor, continuity or clamp modes.
Data Hold Feature
Press the Hold button on the side of the meter to toggle in and out of the data
hold mode. "HOLD" appears in the upper left of the meter display when data hold
is active. Use the data hold feature to lock a measurement reading on the display.
Press the Hold button again to unlock the display and obtain a real-time reading.
MAX/MIN Feature
The MAX/MIN records the maximum and minimum measured value. Press the MAX/
MIN button to activate this feature and to toggle between MAX, and MIN readings.
The unit will continually capture MAX and MIN values over time. Depressing the
MAX/MIN button for >2 sec. exits the MAX/MIN mode.
Relative Mode
Press the "
" button to enter the Relative mode. The "
and the value on the display is stored as a reference value. In the Relative mode, the
value shown on the display is always the difference between the stored reference
value and the present reading. Press the "
" symbol is displayed,
" button again to exit the Relative mode.
Au
Th
any
po
to
dis
Ba
Pre
bac
the
pre
10