DEMAND INITIATED TREATMENT SYSTEM
· SERVICE FLOW RATE = 10.0 GPM (37.8 LPM)
· DRAIN FLOW RATE: 2.0 GPM (7.6 LPM)
· PSI DROP @ FLOW RATE: 12.0 psi (0.9 kgf/cm 2)
· OPERATING PSI OF SUPPLY: 20 psi - 120 psi
(1.47 - 8.45 kgf/cm 2 )
· OPERATING TEMPERATURE: 40° F - 100° F
(4.4° C - 38° C)
· ELECTRICAL: 24 VAC, 50/60 Hz (COMPUTER)
· SALT PER REGENERATION: VARIABLE
· EFFICIENCY: 4,970 GRAINS/LBS. SALT @
3.0 LBS. DOSAGE
LIST OF CONTAMINANTS REDUCED
CONTAMINANT
BARIUM*
RADIUM 226/228*
NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate
*HARDNESS WAS USED AS A SURROGATE FOR BARIUM AND RADIUM REDUCTION CLAIMS PER NSF/ANSI
STANDARD 44.
SOFTENING PERFORMANCE TEST
CHALLENGE
AVERAGE INFLUENT LEVEL
HARDNESS
NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate
ADDITIONAL NOTES
• THE LIST OF SUBSTANCES WHICH THIS TREATMENT DEVICE REDUCES DOES NOT NECESSARILY MEAN THAT THESE
SUBSTANCES ARE PRESENT IN YOUR WATER SUPPLY.
• ACTUAL RESULTS MAY VARY DUE TO LOCAL WATER CONDITIONS.
• AN EFFICIENCY RATED WATER SOFTENER IS A DEMAND INITIATED REGENERATION SOFTENER, WHICH ALSO
COMPLIES WITH SPECIFIC PERFORMANCE SPECIFICATIONS INTENDED TO MINIMIZE THE AMOUNT OF REGEN-
ERATE BRINE AND WATER USED IN ITS OPERATION AND WILL ACHIEVE A RATING OF NOT LESS THAN 3,350
GRAINS OF TOTAL HARDNESS EXCHANGE PER POUND OF SODIUM CHLORIDE SALT AND SHALL NOT DELIVER MORE
SALT THAN ITS LISTED RATING. THE EFFICIENCY IS MEASURED BY A LABORATORY TEST DESCRIBED IN NSF/ANSI
44. THE TEST REPRESENTS THE MAXIMUM POSSIBLE EFFICIENCY THAT THE SYSTEM CAN ACHIEVE. OPERATIONAL
EFFICIENCY IS THE ACTUAL EFFICIENCY ACHIEVED AFTER THE SYSTEM HAS BEEN INSTALLED AND IS TYPICALLY
LESS THAN THE TESTED EFFICIENCY DUE TO INDIVIDUAL APPLICATION FACTORS INCLUDING WATER HARDNESS,
WATER USAGE, AND OTHER CONTAMINANTS THAT REDUCE THE SOFTENERS CAPACITY.
• A WATER SOFTENER IS NOT INTENDED TO BE USED FOR TREATING WATER THAT IS MICROBIOLOGICALLY UNSAFE
OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE AND AFTER THE SYSTEM.
• EFFICIENCY OF THE CONDITIONER IS VALID ONLY AT THE STATED SALT DOSAGE.
IMPORTANT NOTICE
READ THIS PERFORMANCE DATA SHEET AND COMPARE
THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL
WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT
BEFORE PURCHASING A WATER TREATMENT UNIT, YOU
HAVE YOUR WATER SUPPLY TESTED TO DETERMINE YOUR
ACTUAL WATER TREATMENT NEEDS.
EC5 100 CV
USEPA
MCL
2 PPM
5 PCI/L
AVERAGE EFFLUENT LEVEL
335 PPM
8 PPM
DEMAND INITIATED
WATER TREATMENT SYSTEM
PERFORMANCE DATA SHEET
CAPACITY AND SALT SETTINGS
CAPACITY
14,900 GRAINS
32,300 GRAINS
37,700 GRAINS
THE SYSTEM SHOULD BE INSTALLED IN AN AREA NOT
AFFECTED BY EXTREME HEAT, COLD, OR THE ELEMENTS.
THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH
ALL
APPLICABLE STATE AND LOCAL LAWS AND REGU-
LATIONS.
DO NOT INSTALL SYSTEM WHERE WATER IS MICROBIO-
LOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT
ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
THE SYSTEM CONTAINS AN ION-EXCHANGE MEDIA FOR
REMOVING LISTED CONTAMINANTS AND MUST BE REGEN-
ERATED PERIODICALLY. PLEASE REFER TO THE OWNERS
MANUAL
TO
DETERMINE
REGENERATIONS.
PLAIN, WHITE BLOCK SALT IS RECOMMENDED FOR THIS
SYSTEM. IF BLOCK SALT IS NOT AVAILABLE, A CLEAN,
COARSE OR EXTRA COARSE ROCK OR SOLAR SALT MAY BE
USED. DO NOT USE GRANULATED SALT. CONSULT YOUR
RAINSOFT DEALER FOR POTASSIUM CHLORIDE USE.
YOUR LOCAL DEALER IS AVAILABLE FOR SERVICE AND
WARRANTY PART REPLACEMENTS.
SEE THE OWNERS MANUAL FOR GENERAL
MAINTENANCE REQUIREMENTS.
SEE WARRANTY CARD FOR SPECIFIC
TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI
STANDARD 44 FOR THE SPECIFIC PERFORMANCE
CLAIMS AS VERIFIED AND SUBSTANTIATED BY
TEST DATA
TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI
STANDARD 372 FOR LOW LEAD COMPLIANCE
THE EC5 SERIES IS TESTED AND CERTIFIED
BY WQA TO CSA B483.1 STANDARD.
SALT
@ 3.0 LBS. OF SALT
@ 10.0 LBS. OF SALT
@ 15.0 LBS. OF SALT
THE
FREQUENCY
OF
OPERATION AND

WARRANTY INFORMATION.