W W A A T T E E R R T T R R E E A A T T M M E E N N T T S S Y Y S S T T E E M M
The EC4 series is tested and certified by the WQA to NSF/ANSI 44 for the specific performance
claims as verified and substantiated by test data. See the performance data sheet for specific
reduction claims.
The EC4 series is tested and certified by WQA to NSF/ANSI 372 for California "lead free" compliance.
E E C C 4 4 S S E E R R I I E E S S
Part No.: 15929
Rev: M
04/13

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EC4 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for RainSoft EC4 SERIES

  • Page 1 W W A A T T E E R R T T R R E E A A T T M M E E N N T T S S Y Y S S T T E E M M ™ The EC4 series is tested and certified by the WQA to NSF/ANSI 44 for the specific performance claims as verified and substantiated by test data. See the performance data sheet for specific reduction claims.
  • Page 2: Table Of Contents

    Table of Contents Information on Water Treatment Systems ..........3 Application Limitations ................3 Operational Specifications ..............4 _ 6 Salt Requirements ..................7 Resin Cleaners....................7 Maintenance Requirements................7 Product Certification Information.............. 7 Installation Instructions ................ 8 _ 11 System Start Up....................
  • Page 3: Information On Water Treatment Systems

    Questions? If you have any questions regarding the installation, oper- ation, or servicing of this system, please contact your local RainSoft Dealer. Your local RainSoft Dealer is familiar with your particular water conditions, and is able to address your concerns promptly and efficiently.
  • Page 4 Operational Specifications Plumbing 3/4 inch to 1 1/4 inch I.D. Drain Line 1/2 inch I.D. Water Pressure 20 psi _ 120 psi (1.38 bar _ 6.89 bar) Operating Temperatures 40° F _ 100° F (4.4° C _ 37.8° C) Electrical Requirements A properly grounded alternating current supply (110 VAC 60 Hz or 230 VAC 50 Hz) is required for the operation of this system.
  • Page 5 Data Chart for ION-X 2000 V Resin Cation Max. Tank Drain Exchange Service High Medium * * The conditioners are efficiency rated Model Size Flow psi Drop Efficiency* Resin Flow Salting Salting Salting according to NSF/ANSI 44. The efficiency of the (inches) (gpm) (cu.
  • Page 6: Operational Specifications ...................................................................... 4

    Operational Specifications continued from page 5 Data Chart for ION-X 100 T Resin The conditioners are efficiency rated Cation Max. Drain according to NSF/ANSI 44. The efficiency of Tank Size Exchange Service High Medium Model Flow psi Drop Efficiency* the conditioner is valid only at the stated salt (inches) Resin Flow...
  • Page 7: Salt Requirements

    Please refer to the performance data sheets for specific reductions claims. The EC4 Series is tested and certified by WQA to NSF/ANSI 372 for California “lead free” compliance. Water treatment devices sold to retail consumers in California, accom- panied by certain health claims, must be certified by the State of California Department of Public Health.
  • Page 8: Installation Instructions

    Installation Instructions 1. Safety Precautions Important Note: For Massachusetts Residents Only: The Commonwealth of • To prevent an accident and/or injury, do not hoist the unit over Massachusetts Plumbing Code 248 CMR your shoulder. Use a hand truck to transport the unit. shall be adhered to.
  • Page 9 Important Note: Short connec- • Do not point the soldering torch directly at the mineral tank or tions of pipe may allow hot water control valve. These composite materials will last a lifetime, but to back up into the system. cannot withstand the intense heat from a torch.
  • Page 10 Installation Instructions continued from page 9 Install the Drain Line and Air Gap (Air Gap Not Supplied) • For all drain lines, use at least a 1/2 inch I.D. line. • Connect the drain line to the drain outlet on back of the valve, opposite the inlet connection (see figure 4).
  • Page 11 Install the Brine Line Important Note: Not Applicable for EC4-CAB Models. • Slide the brass compression nut over the end of the brine line, followed by the ferrule and tube support. Attach the brine line to the brass fitting on the right side of the valve (see figure 7). •...
  • Page 12: System Start Up

    System Start Up 1. Turn on the Water and Check for Leaks • Close all faucets and turn the water back on at the water meter or pressure tank. • Check for leaks. If a leak is present, drain the plumbing again before soldering.
  • Page 13: An Overview Of The Regeneration Process

    An Overview of the Regeneration Process Your RainSoft EC4 Water Conditioner performs a periodic regeneration cycle to clean itself and restore its capacity. How often it regenerates depends on your water use, incoming water hardness, and several other factors, but 1 - 2 times a week is typical. An automatic regeneration will never occur more than once in a day, and is programmed to occur at a time when you are unlikely to be using water (late at night in most cases).
  • Page 14 Brine Draw / Slow Rinse Cycle After the system is backwashed for several minutes, the valve moves to the brine draw position. In this posi- tion, the valve creates a vacuum to pull the brine solution out of the brine tank. The brine solution flows slowly through the mineral bed, removing the hardness ions that are attached to the softening resin and sending them to the drain.
  • Page 15: Customer Settings

    • Use the Adjust Up and Adjust Down keys to change the amount of through your RainSoft Dealer, part number 19024. salt to the level indicated on the salt tank scale (located on the side of Important Notes: After setting the the salt tank).
  • Page 16: How To Initiate A Manual Regeneration

    Customer Settings continued from page 15 The computer will display: Salt Alarm– ON • Use the Adjust Up or Adjust Down key to select “OFF”. • If you chose to keep the alarm “ON”, press the Menu Forward key. Use Helpful Tip: Your system is designed to alert you when the the Adjust Up and Adjust Down keys to change the alarm time, if...
  • Page 17: System Alarms

    Settings” on page 13 for instruc- you wish to postpone the alarm. Press the Enter key after the number tions on adding salt. of days has been selected. Service Required Alarms: Please contact your local RainSoft Dealer for service. Understanding the Information Center...
  • Page 18: Troubleshooting Guide

    2. Excessive water pressure. 2. Install a pressure regulator. If the troubleshooting guide did not resolve the symptom, please contact your local RainSoft Dealer for service. If you cannot locate your local RainSoft Dealer, please contact RainSoft Customer Service at 1-800-860-7638 or logon...
  • Page 19: Warranty Information

    The defective part(s) (or entire unit) will either be repaired or new RainSoft part(s) furnished, for a nominal charge to cover labor, handling, packing and the increase, if any, in the retail price of the part(s) since the date of purchase.
  • Page 20: Exploded Views And Parts Lists

    Valve Exploded View...
  • Page 21 Valve Parts List Item Quantity Part Number Description 17863 Composite valve body 17864 Spacer end 17865 Internal spacer 17866 Internal seal 18160 Retainer & down flow piston 10258 O-ring - 017 17869 End plug assembly 17870 10-24 x .812 screw hex washer head 17871 Piston rod 17887...
  • Page 22 Control Exploded View...
  • Page 23 Control Parts List Item Quantity Part Number Description 17487 Rear housing 17501 Brine cam gear 17492 Brine cam gear bracket 17537 Valve motor w/computer cam 24v 50/60 hz 17526 Switch 45 deg actuator gold contact 19536 Sealed switch C-NC male connector red 19537 Sealed switch C-NO female connector brown 17548...
  • Page 24: California Performance Data Sheets

    OR EXTRA COARSE ROCK OR SOLAR SALT MAY BE USED. DO NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate NOT USE GRANULATED SALT. CONSULT YOUR RAINSOFT DEALER FOR POTASSIUM CHLORIDE USE.
  • Page 25 Replacement Elements RainSoft EC4 75 CV Manufacturer: RainSoft, A Division of Aquion, Inc. The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:...
  • Page 26 NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate COARSE ROCK OR SOLAR SALT MAY BE USED. DO NOT USE GRANULATED SALT. CONSULT YOUR RAINSOFT DEALER FOR POTASSIUM CHLORIDE USE.
  • Page 27 Replacement Elements RainSoft EC4 100 CV Manufacturer: RainSoft, A Division of Aquion, Inc. The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:...
  • Page 28 OR EXTRA COARSE ROCK OR SOLAR SALT MAY BE USED. DO NOT NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate USE GRANULATED SALT. CONSULT YOUR RAINSOFT DEALER FOR POTASSIUM CHLORIDE USE.
  • Page 29 Replacement Elements RainSoft EC4 150 CV Manufacturer: RainSoft, A Division of Aquion, Inc. The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:...
  • Page 30 ™ RainSoft Division of Aquion, Inc. 2080 East Lunt Avenue Elk Grove Village, Illinois 60007 Main Switchboard: 1.847.437.9400 Customer Service: 1.800.860.7638 www.rainsoft.com ©2013 RAINSOFT, A DIVISION OF AQUION, INC.
  • Page 31 Rainsoft División de Aquion, Inc 2080 Avenida Este Lunt Elk Grove Village, Illinois, 60007 1.847.437.9400 or 1.800.860.7638 www.rainsoft.com Tomando la preocupación fuera del agua Desde 1953 S S E E R R I I E E E E C C 4 4...
  • Page 32 Indice de Materias Información del Sistema de Tratamiento de Agua........33 Aplicación de Restricciones ................33 Especificaciones de Operación ............34-36 Requisitos de la Sal ..................37 Limpiadores de Resina................37 Requisitos de Mantenimiento ..............37 Información de la Certificación del Producto ........37 Instrucciones para la Instalación ............38-41 Sistema de Puesta en Marcha..............42 Una Visión general del proceso de regeneración.........43-44...
  • Page 33: Información Del Sistema De Tratamiento De Agua

    Sistema. En aplicaciones donde los altos niveles son una preocupación es necesaria una pre-filtración para reducir el cloro o cloramina a un nivel aceptable. Ver su distribuidor de RainSoft para detalles. • Cuando el sistema es instalado en agua con Hierro Ferroso también...
  • Page 34: Especificaciones De Operación

    2 a 10 partes por millón. Su equipo podría requerir una programación especial asi como un aditivo al tanque de salmuera para maximizar la capacidad del equipo en remover el hierro. Ver su distribuidor RainSoft para detalles. Especificaciones de Operación Tuberia: 3/4 pulgada por 1 1/4 pulgada I.D.
  • Page 35 Cuadro de Datos para Resina ION-X 2000 V * El índice de eficacia de los acondi- Resinas de Velocidad Caída cionadores está de acuerdo con NSF/ANSI Tamaño Drain Intercambio Maximo de High Medium 44.La eficacia del acondicionador es válida Modelo del Tanque Flow Eficiencia*...
  • Page 36 Operational Specifications continued from page 33. Cuadro de Datos para Resina ION-X 100 T * El índice de eficacia de los acondi- Tamaño Resinas de Velocidad Drain Caída de cionadores está de acuerdo con NSF/ANSI Intercambio Maximo de High Medium Modelo Flow Presión...
  • Page 37: Requisitos De La Sal

    RainSoft al tanque de sal cuando le agregue la sal. Si tiene una cantidad exce- siva de hierro en el agua le recomendamos la instalación de un filtro de hierro Nota Importante: Si ud.
  • Page 38: Instrucciones Para La Instalación

    Instrucciones para Instalación 1. Medidas de Precaución Nota Importante: Para residentes de •Para prevenir un accidente y/o daño no levante la unidad sobre su Massachusetts solamente: Se deberá respetar el Codigo 248 CMR de la hombro. Utilice un camión de mano para transportar la unidad. Mancomunidad Plomeria Massachusetts.
  • Page 39 • Evite conecciones cortas del tubo entre el sistema y el calentador Nota Importante: Conexiones de de agua. Si Ud. no lo pudiera evitar mueva el sistema a otra ubicación. tubo corto puede permitir agua caliente retroceder dentro del Como último recurso instale una trampa de calor o válvula de detec- sistema.
  • Page 40 Installation Instructions continued from page 39 Instalar la Linea de Desague y Boquete de Aire (boquete de aire no proporcionada) • Para todas las líneas de desague use una línea de por lo menos 1/2 pulgadaI.D. • Conecte la linea de desague a la salida del desague atrás de la válvula en frente a la conexión de la entrada (ver figura 4).Se requiere un accesorio para conectar la rosca del tubo hembra a la línea del desague.
  • Page 41 Instalar la Linea de Salmuera Nota Importante: No Aplicable para modelo EC4-CAB . • Deslice la tuerca de lata de compresión sobre el final de la línea de salmuera seguido por el regetón y tubo de apoyo.Unir la linea de salmuera al accesorio de lata en el lado derecho de la válvula.
  • Page 42: Sistema De Puesta En Marcha

    Sistema de Puesta en Marcha 1. Encienda el agua y verifique que no haya fugas • Cerrar todas las cañerias y vuela a abrirlas en el medidor de agua o tanque de presión. • Verifique que no haya fugas. De presentar fugas vacie la tuberia nuevamente antes de soldarla.
  • Page 43: Una Visión General Del Proceso De Regeneración

    Una Visión general del proceso de regeneración Su Acondicionador de Agua RainSoft EC4 desarrolla un ciclo de regeneración periódica para limpiarse a si mismo y restaurar su capacidad. Con que frecuencia se regenere depende de su uso de agua, de la dureza del agua, y varios otros factores, pero 1 - 2 veces a la semana típicamente.
  • Page 44 Extracción de Salmuera / Ciclo lento de enjuague Después que el sistema es lavado por varios minutos, la válvula se mueve a la posición de extracción de salmuera. En esta posición, la válvula crea un vacío para extraer la solución de salmuera el tanque de salmuera. La solución de salmuera fluye lentamente a través de la capa de minerales, eliminando los iones de dureza que se adjuntan en la resina de ablandamiento y enviándolos al desagüe.
  • Page 45: Configuraciones Del Cliente

    • Use las teclas de Ajustar hacia arriba y Ajustar hacia abajo para RainSoft, parte númbero 19024. cambiar la cantidad de sal al nivel indicado en la escala del tanque de sal ( ubicado en el lado del tanque de sal.
  • Page 46 Customer Settings continued from page 45. La Computadora mostrará: Alarma de Sal–ENCENDIDO. • Usar la tecla de Ajustar hacia Arriba o Ajustar hacia Abajo para seleccionar “APAGADO”. • Si Ud. ha elejido mantener la alarma “ENCENDIDO” presione la tecla Adelantar del Menú Use las teclas para Ajustar hacia Arriba y Ajustar hacia para alertarlo cuando el tanque Abajo para cambiar la hora de alarma, si lo desea.
  • Page 47: Como Iniciar Una Configuración Manual

    Presione la tecla Iniciar luego de haber seleccionado el número de días. posponer.Favor referirse a la pág. 13 de Configuraciones para el Alarma de se Requiere Servicio: Favor contactar su distribuidor local de RainSoft para Cliente para instrucciones de mantenimiento.
  • Page 48: Solución De Problemas

    Si la guia de solución de problemas no resuelve estos indicios, favor contactárse con su distribuidor local de RainSoft para servicio. Si Ud. no puede localizar a su distribuidor local de RainSoft, favor comuníquese al Servicio al Cliente de RainSoft al 1-800-860-7638 o entrar a www.rainsoft.com para el nombre y dirección de distribuidor...
  • Page 49: Información De La Garantía

    RainSoft será suministrada por un pequeño costo que incluye mano de obra, empaquetar, enviar y la subida de precio, si hubiera , en el precio de las partes desde el dia de la compra. Partes originales de RainSoft serán usadas. La falla de usar piezas originales de RainSoft anulará...
  • Page 50: Vista Detalla Y Lista De Partes

    Vista Detallada de la Válvula...
  • Page 51 Lista de Partes de la Válvula Artículo Cantidad Número de Parte Descripción 17863 Composite valve body 17864 Spacer end 17865 Internal spacer 17866 Internal seal 18160 Retainer & down flow piston 10258 O-ring - 017 17869 End plug assembly 17870 10-24 x .812 screw hex washer head 17871 Piston rod...
  • Page 52 Vista Detallada de Control...
  • Page 53 Lista de Partes de Control Artículo Cantidad Número de Parte Descripción 17487 Rear housing 17501 Brine cam gear 17492 Brine cam gear bracket 17537 Valve motor w/computer cam 24v 50/60 hz 17526 Switch 45 deg actuator gold contact 19536 Sealed switch C-NC male connector red 19537 Sealed switch C-NO female connector brown 17548...
  • Page 54: Hoja De Datos De Funcionamiento De California

    NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate LIMPIA, GRUESA O EXTRA GRUESA O SAL SOLAR. NO USE SAL GRANULADA. CONSULTE SU DISTRIBUIDOR DE RAINSOFT POR NOTAS ADICIONALES EL USO DE CLORURO DE POTASIO.
  • Page 55 Replacement Elements RainSoft EC4 75 CV Manufacturer: RainSoft, A Division of Aquion, Inc. The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:...
  • Page 56 NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate Y PURA. DE NO SER DISPONIBLE PUEDE USARSE SAL EN ROCA LIMPIA, GRUESA O EXTRA GRUESA O SAL SOLAR. NO USE SAL GRANULADA. CONSULTE SU DISTRIBUIDOR DE RAINSOFT POR NOTAS ADICIONALES EL USO DE CLORURO DE POTASIO.
  • Page 57 Replacement Elements RainSoft EC4 100 CV Manufacturer: RainSoft, A Division of Aquion, Inc. The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:...
  • Page 58 NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate LIMPIA, GRUESA O EXTRA GRUESA O SAL SOLAR. NO USE SAL GRANULADA. CONSULTE SU DISTRIBUIDOR DE RAINSOFT POR NOTAS ADICIONALES EL USO DE CLORURO DE POTASIO.
  • Page 59 Replacement Elements RainSoft EC4 150 CV Manufacturer: RainSoft, A Division of Aquion, Inc. The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:...
  • Page 60 ™ RainSoft División de Aquion, Inc. 2080 Avenida Este Lunt Elk Grove Village, Illinois, EEUU 60007 Principal Conmutador: 1.847.437.9400 Servicio al Cliente: 1.800.860.7638 www.rainsoft.com ©2013 RainSoft, Una División de Aquion, Inc.