Uninstalling the data package Uninstallation can also be done manually from Windows Control Panel / Add / Remove Pro- grams/ -> RM-94 Phone Data Package. If you try to install the same version of Phoenix data package that you already have, you are asked if you want to uninstall the current version.
First, fill in the “FPS-8 activation request” sheet in the FPS-8 sales package and follow the in- structions in the sheet. When the activation file is received (e.g. 00000.in), copy it to C:\ProgramFiles\Nokia\Phoe- nix\BoxActivation directory on your computer. (This directory is created when Phoenix is in- stalled.)
Page 38
After you have installed or updated the JBV-1 USB driver, the actual JBV-1 SW update can be- gin. Go to folder C:\Program Files\Nokia\JBV-1 Firmware Update\JBV-1 Firmware Update and start JBV-1 Update SW by double clicking fwup.exe. The JBV-1 Firmware update starts and shows the current status of the JBV-1 connected.
Note: In later Phoenix versions the notch calibration might not be applicable anymore. TX power level tuning RM-94 supports GMSK and EDGE mode for the Power amplifier. Therefore, the power level tuning must be carried out for both modes in each band.