NEM-4
BB Troubleshooting
Energy management calibration
During energy management calibration A/D-converter, BSI, Btemp, Battery voltage,
Charger voltage and Charger current are calibrated.
Limits for calculated calibration values are as follows:
ADC-offset over limits:
Inspect BSI line and components in it (R385, Pull-up resistor R220). If these are OK,
change UEM.
BSI Gain over limits:
Inspect BSI line and components in it (R385, Pull-up resistor R220). If these are OK,
change UEM.
Page 6(a)-24
Company Confidential
Channel
Low
ADC Offset
-50
ADC Gain
26000
BSI Gain
860
Vbatt Offset
2400
Vbatt Gain
10000
Vchar
57000
Ichar
3600
Copyright 2003 Nokia Corporation
Company Confidential
CCS Technical Documentation
High
50
29500
1180
2600
11000
63000
5000
Issue 1 09/2003