Download Print this page

Cebekit UCPIC-6 Manual

Circuit picaxe 08m2 4 relays

Advertisement

Quick Links

It incorporates micro PICAXE 08M2. Pushbutton digital input, 4 relays output 2 amps. Power indicator LEDs and
relays. Connector recording.
Indicator automation development requiring external control switch with, for example, sequential, timers.
Important : maximum allowable voltage PIN 3 : 5VDC
Il intègre micro PICAXE 08M2. entrée Pushbutton numérique, 4 relais de sortie 2 ampères. Indicateurs LED
alimentation et relais. Connecteur pour enregistrement.
Indicateur de développement d'automatisation exigeant commutateur de contrôle externe avec, par exemple,
séquentielle, temporisateur.
Important : maximum PIN de tension admissible 3 : 5VDC
Incorpora micro PICAXE 08M2. Entrada digital con pulsador, 4 relés de salida 2 Amp. Leds indicadores de
alimentación y relés. Conector de grabación.
Indicador para el desarrollo de automatismo que requiera control externo con un pulsador y potenciómetro, por
ejemplo, secuencial, temporizador.
Importante : Tensión máxima admisible PIN 3 : 5VDC
Circuit PICAXE 08M2 - 4 Relays
Circuit PICAXE 08M2 - 4 Relais
Circuito PICAXE 08M2 - 4 Reles
www.cebekit.com
-
UCPIC-6
Characteristic
Voltage : 12 V DC
Minimum consumition
Maximum consumition : 135 mA
Supported Picaxe
Relay Maximum Load : 2 Amp / 230 VAC
Protection reverse polarity : yes
Recommended power supply :
Size : 121 x 72 x 30 mm.
Din rail : C-7569
info@cebekit.com
: 15 mA
:
08M2 /08M
FE 103

Advertisement

loading

Summary of Contents for Cebekit UCPIC-6

  • Page 1 Circuit PICAXE 08M2 - 4 Relays Circuit PICAXE 08M2 - 4 Relais Circuito PICAXE 08M2 - 4 Reles UCPIC-6 Characteristic Voltage : 12 V DC Minimum consumition : 15 mA Maximum consumition : 135 mA Supported Picaxe 08M2 /08M Relay Maximum Load : 2 Amp / 230 VAC...
  • Page 2 UCPIC-6 -Pin3: It has the function button. If you activate its value will be 1 if it is not, its value will be 0 -Pin0, Pin1, pin2 and pin4 correspond to the outputs, connected relays, indicated by leds. IMPORTANTE : DEPARTURES ARE NOT POSITIONED IN ORDER.
  • Page 3 UCPIC-6 1The instruction pause = milliseconds. To change it, write "pause X", where X desired milliseconds. We can also use the wait instruction, which is measured in seconds; 4 = wait wait 4 seconds. To change the value, type "wait X", where X desired seconds.
  • Page 4 UCPIC-6 Pause instruction 200, it is to avoid unsuccessful pulses Pause instruction 200, il est d'éviter des impulsions infructueuses Instrucción pause 200 , es para evitar pulsos fallidos PRACTICE 3 Put switch S4 in position to load the program record, finishing work put position.
  • Page 5 UCPIC-6 PRACTICE 4 Put switch S4 in position to load the program record, finishing work put position. In practice, if you press the button output is activated and so on. When all outputs are and we press the button again, they will turn off at once.
  • Page 6 UCPIC-6 PRACTICE 5 Put switch S4 in position to load the program record, finishing work put position. We just UPIC6 programs with the simplest of all program. We have a status button and, if it is true, the outputs are activated and deactivated sequentially.
  • Page 7 UCPIC-6 230V www.cebekit.com info@cebekit.com...
  • Page 8 UCPIC-6 Important: Never remove or insert the picaxe with the power on, irreparably damage it. Important: Ne jamais retirer ou insérer le picaxe sous tension, endommager de façon Irréparable Importante : Nunca extraiga o inserte el picaxe con la alimentación conectada , lo dañaría irreparablemente www.cebekit.com...