Electric Wiring Work - Gree Versati III GRS-CQ8.0Pd/NhH-M Owner's Manual

Air-to-water heat pump split
Hide thumbs Also See for Versati III GRS-CQ8.0Pd/NhH-M:
Table of Contents

Advertisement

Air-to-water Heat Pump Split Versati
Description
Circulating water inlet/outlet of main unit
Cooling water inlet of water tank
Circulating water inlet/outlet of water tank
Hot water outlet of water tank
Code
01842800004P01
Retaining Plate Sub-Assy
70210087
70110066
Swell Screw M8X60
0738280101
035033000012
Water Pipe Connector
06332800003
75042805
030059000120
Water inlet pipe sub-assy
05332800002
Drainage Pipe(Rubber)
70814016
2690280000502
0184280000502P
Notes
(a) Distance between indoor unit and water tank should not exceed 5m levelly and 3m vertically. If higher,
please contact with us. Water tank on lower and main unit on higher side is recommended.
(b) Prepare the materials according to the above joints dimension. If cut-off valve is installed outside the room,
PPR pipe is recommended to avoid freeze damage.
(c) Waterway pipelines can't be installed until water heater unit is fixed. Do not let dust and other sundries
enter into pipeline system during installation of connection pipes.
(d) After connection of all waterway pipelines, perform leakage test firstly. After that, perform heat preservation
of waterway system; meanwhile, pay more attention to valves and pipe joints. Ensure enough thickness of
insulated cotton. If necessary, install heating device for pipeline to prevent the pipeline from freezing.
(e) Hot water supplied from insulated water tank depends on pressure of water tap, so there must be supply of
tap water.
(f) During using, the cut-off valve of cooling water inlet of water tank should be kept normally on.

18.4 Electric wiring work

18.4.1 Wiring principle
General principles
(1) Wires, equipment and connectors supplied for use on the site must be in compliance with provisions of
regulations and engineering requirements.
(2) Only electricians holding qualification are allowed to perform wire connection on the site.
(3) Before connection work is started, the power supply must be shut off.
(4) Installer shall be responsible for any damage due to incorrect connection of the external circuit.
(5) Only copper wires are allowed to be used.
(6) Connection of power cable to the electric cabinet of the unit
(7) Power cables should be laid out through cabling trough, conduit tube or cable channel.
Name
QTY.
2
Bolt M6X16
4
2
Relief Valve 1/2
1
1
Nut
1
Gasket
2
2
1
Pipe Hoop φ13
1
Extruded strip
1
Fixing strap
1
Joint pipe thread
3/4"Female BSP
3/4"Female BSP
3/4"Female BSP
Function
Fix the water tank to the wall
/
/
/
Connect the water pipe and Water inlet pipe sub-assy
Install on the 3way connector
Sealing function, see below blue circle
/
The drainage pipe using for the relief valve to drainage the
water
Fix the drainage pipe
Fix the water tank and avoid the damage appearance of the
water tank
Fix the water tank to the wall
34
SPLIT
TYPE
1"Male BSP