SHIPPING COMPONENTS
The unit is shipped in two separate cartons; the first
carton is for the water heater tank. The second is for
the burner and aquastat(s), the wiring harness, safety
relief valve and the flue adaptor.
CM-32/CMO32
Sides
5.08 cm (2")
Rear
5.08 cm (2")
Top
45.70 cm (18")
Front
61.00 cm (24")
Flue
22.90 cm (9")
6)
WATER CONNECTIONS
CAUTION
To avoid water damage and/or scalding due to relief
valve operation, a discharge line must be connected to
the valve outlet and run to a drainage area. The
discharge line shall be installed in such a way that it
will allow for complete drainage of the valve and
discharge line.
Make the hot and cold water connections to the water
heater. Do not apply heat to the hot water outlet and
cold water inlet, as they contain a plastic sleeve inside.
Pressure relief valves are installed on models CM-32,
CMO32 and CMO50.
7)
FLUE PIPE
The water heater should be connected to a chimney or
an approved pre-fabricated flue. The flue pipe should
be the same size as the flue outlet of the unit. It is
preferable to maintain a pitch or rise from the heater to
the chimney of 2.0 cm per 1 m (1/4" per foot). The flue
pipe must not be extended past the inside wall of the
chimney.
8)
DRAFT REGULATOR
The draft regulator must be installed between the flue
outlet of the water heater and the chimney.
(Installation
instructions
regulator).
9)
BLOCKED VENT SHUT-OFF (BVSO)
For chimney venting
WARNING
IT IS IMPERATIVE THAT THIS DEVICE BE
INSTALLED BY A QUALIFIED TECHNICIAN.
4
CMO50
15.20 cm (6")
15.20 cm (6")
45.70 cm (18")
61.00 cm (24")
22.90 cm (9")
are
furnished
with
the
This device is designed to detect the insufficient
evacuation of combustion gases in the event of a vent
blockage. In such a case the thermal switch will shut
down the oil burner. The device will then need to be
re-armed MANUALLY.
Refer to the wiring diagrams and the detailed
instructions supplied with the BVSO for the installation
and wiring procedure. The length of wires supplied
with the unit is such that the safety device must be
installed between the flue outlet of the appliance and
the draft regulator, as indicated in the instructions.
It is further imperative that the BVSO be maintained
annually. Refer to the instructions supplied with the
device and paragraph 24.1), p. 6 of this manual for
more details.
CAUTION
A
positive
pressure
Combustion System or Direct Vent) MUST NOT use
the BVSO. Follow the instructions supplied with the
venting system.
10) CHIMNEY
WARNING
An oil-fired unit shall be connected to a flue
having sufficient draft at all times to assure
proper operation of the unit.
For information pertaining to chimney sizes, elevation,
conditions,
etc.,
see
"Installation code for oil burning equipment."
11) CONTROLS
Mount the aquastat control on the unit. Set operating
control between 48°C (120°F) and 60°C (140°F). The
latter being the maximum setting for models CM-32,
CMO32 and CMO50.
12) BVSO PERFORMANCE TEST
The purpose of the following test is to check that the
electrical outlet on the furnace, designated to the BVSO,
is functional.
1.
Start up the burner;
2.
Remove the three-pole plug from the BVSO outlet
on the furnace;
3.
The burner must shut-off immediately.
If the test is not in line with the above, call a QUALIFIED
SERVICE TECHNICIAN.