Proper Use
The module is for monitoring signal transmitters (e.g. emergency stop
buttons, position switches, electro sensitive protective equipements
ESPE), that are used as part of the safety equipment of machines for the
purpose of protecting people, material and machinery.
Note
• The performance level and safety category in accordance with
EN ISO / ISO 13849-1 depends on the external wiring, the application
case, the choice of control station and how this is physically arranged
on the machine.
• The user must carry out a risk assessment in accordance with
EN ISO / ISO 14121-1.
• The entire system/machine must undergo validation in accordance
with the applicable standards on the basis of this.
• The module contains electro-mechanical relays. Therefore his
indicated performance level and his MTTF
and on the operating cycles in the application. The above mentioned
performance level and MTTF
d
maximum 6,336 switching cycles per year or for low load and
maximum 316,800 switching cycles per year.
• If the current load is known, use the diagram for the electrical service
life (see page 18/20) to calculate the maximum number of switching
cycles. The specified performance level can only be assured for
the number of switching cycles calculated using this method. The
device must be replaced on reaching this maximum figure.
Thereby the lifetime of the device must not be exceeded.
• Operating the device not within the specifications may lead to
malfunctions or the destruction of the device.
• The supply input A1 serves as a control input. This may lead to short
disruptions or a lowering below the operating voltage U
switch to the release path.
• Expansion devices or external contactors with positively driven
contacts can be used to duplicate the enabling current paths.
• The emergency stop chain must be closed before the reset button is
activated.
• If magnetic switches with reed contacts or sensors with semiconductor
outputs are connected the switch ON peak current must be noticed
(see Technical Data).
• Please consult the installation notes.
Note
Please observe instructions from safety authorities.
Note
There are no user serviceable components in the module. For safety
circuits according to EN / IEC 60204-1, EN ISO / ISO 13850 safety
devices must use only the hard contact outputs between terminals 13-14,
23-24 and 33-34.
CAUTION
RESIDUAL RISK (EN ISO / ISO 12100-1)
The following wiring diagram has been tested and tried carefully under
actual service conditions. This module must be used for safety-related
functions in conjunction with the connected safety equipment and
devices that meet applicable standard requirements. A residual risk will
remain if:
a) it is necessary to modify this recommended circuit and if the added/
modified components are not properly integrated in the control circuit.
b) the user does not follow the required standards applicable to the
operation of the machine, or if the adjustments to and maintenance of
the machine are not properly made. It is strictly necessary to follow
the prescribed machine maintenance schedule.
c) the user does not select relays K3 and K4 with mechanically-linked
contacts.
Failure to follow this instruction can result in injury or equipment
damage.
10 / 20
value depend on the load
d
values are suitable for nominal load and
in order to
B
WARNING
IMPROPER CIRCUIT AND MAINTENANCE HAZARD
• Wire safety relay using wiring diagram shown in following wiring
diagram.
• Wire to meet applicable standards requirements.
• K3 and K4 must have mechanically-linked contacts.
• Strictly follow prescribed maintenance schedule when making
adjustments to and maintenance of machine.
Failure to follow this instruction can result in death, serious injury,
or equipment damage.
DEUTSCH
GEFAHR
GEFÄHRLICHE SPANNUNG
Die Montage, Inbetriebnahme, Änderung und Nachrüstung darf nur von
einer Elektrofachkraft ausgeführt werden!
Schalten Sie das Gerät/ die Anlage vor Beginn der Arbeiten
spannungsfrei!
Bei Installations und Anlagenfehlern kann bei nicht galvanisch
getrennten Geräten auf dem Steuerkreis Netzpotential anliegen!
Beachten Sie für die Installation der Geräte die Sicherheitsvorschriften
der Elektrotechnik und der Berufsgenossenschaft.
Durch Öffnen des Gehäuses oder sonstige Manipulation erlischt
jegliche Gewährleistung.
Die Nichtbeachtung dieser Anweisung wird Tod oder schwere
Körperverletzung zur Folge haben.
VORSICHT
UNSACHGEMÄSSER GEBRAUCH
Bei unsachgemäßen Gebrauch oder nicht bestimmungsgemäßer
Verwendung darf das Gerät nicht mehr verwendet werden und es
erlischt jeglicher Gewährleistungsanspruch.
Nicht zulässige Einwirkungen können sein:
starke mechanische Belastung des Gerätes, wie sie z.B. beim
Herunterfallen auftritt, Spannungen, Ströme, Temperaturen,
Feuchtigkeit außerhalb der Spezifikation.
Bitte überprüfen Sie gemäß der geltenden Vorschriften bei
Erstinbetriebnahme Ihrer Maschine/ Anlage immer alle
Sicherheitsfunktionen und beachten Sie die vorgegebenen Prüfzyklen
für Sicherheitseinrichtungen.
Die Nichtbeachtung dieser Anweisung kann Körperverletzung
oder Materialschäden zur Folge haben.
VORSICHT
GEFAHR BEI INSTALLATION
Führen Sie vor Beginn der Installation/ Montage oder Demontage
folgende Sicherheitsmaßnahmen durch:
1. Schalten Sie das Gerät/ die Anlage vor Beginn der Arbeiten
spannungsfrei!
2. Sichern Sie die Maschine/ Anlage gegen Wiedereinschalten!
3. Stellen Sie die Spannungsfreiheit fest!
4. Erden Sie die Phasen und schließen Sie diese kurz!
5. Decken und schranken Sie benachbarte, unter Spannung stehende
Teile ab!
6. Der Einbau der Geräte muss in einem Schaltschrank mit einer
Schutzart von mindestens IP 54 erfolgen.
Die Nichtbeachtung dieser Anweisung kann Körperverletzung
oder Materialschäden zur Folge haben.