HOLE CHAMFER MEASUREMENT
S-LINE INTERNAL CHAMFER GAUGE
Thank you for purchasing the S-LINE CHAMFER GAUGE.
This precision instrument performs a simple yet highly accurate measurement of chamfer maximum diameter.
●
For safe and proper use of this product, please read this instruction manual before use and follow the procedures
described. Please keep manual where it is accessible to user for future reference.
●
Keep this manual with the instrument if transferred or leased to a third party.
●
For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page.
■PART IDENTIFICATION
※ Model SCG-4090 shown
2
0
10
190
20
180
3
30
170
40
160
2:1
4
50
150
60
0.01 mm
140
20
38
22
36
24
70
130
34
26
32
28
5
80
30
120
90
110
100
6
1. Dedicated Dial Gauge
※
Can not be removed
or replaced.
2. Limit Markers
3. Pointer
4. Short Hand
5. Bezel
6. Gauge Mount
7. Shaft
8. Meas. Head
9. Ref. Surface
10. Meas. Taper
SPECIFICATION
Measurement
Usable Chamfer
Model
Taper Angle
Angle Range
SCG−2090
90°
90°
or Less
SCG−4090
SCG−20127
90° 〜120°
127°
SCG−40127
Model
INSTRUCTION MANUAL
No.
SAFETY
Always follow the procedures specified below in order to
prevent harm to yourself or others, and to prevent damage to
property.
Indicates risk of
CAUTION:
property damage
1
●
Measurement Head and Measurement Taper are
hardened steel and sensitive to corrosion. Please
keep well protected with rust inhibitor when not in
use.
●
Only use with the dedicated Dial Gauge. Use of
any other gauge will cause reading error.
●
Do not remove Dial Gauge, or loosen the holding
7
screw. Loosening screw will cause reading
inaccuracy.
●
Use care when contacting Measuring Head to
workpiece and avoid impact; there is risk of
damage to Measurement Taper.
●
Instrument is designed for measuring the ID
chamfer max. diameter.
8
Use for any other purpose may cause accident or
injury.
9
APPLICATIONS & FEATURES
●
The chamfer diameter (max diameter) for a
10
range of chamfer angles can be measured.
●
Dedicated Dial Gauge for direct reading of
measurement.
Range
Graduations
Accuracy
(mm)
(mm)
(mm)
0.5〜20
0.01
20〜40
±0.015
0.5〜20
0.02
20〜40
MEASUREMENT
SCG- ***
①
Hold the Measurement Head perpendicular
to the workpiece and slowly push in until
there is no gap between the workpiece
and the Measurement Head Reference
Surface. (Fig. 1)
②
The Dial Gauge will indicate the maximum
diameter of the chamfer. (Fig. 2)
ZERO ADJUSTMENT
PLEASE OBSERVE
Setting Zero Point on Flat Reference Surface
①
A smooth, hard surface is required as Reference
Surface.
or
personal injury
②
Place the Measurement Head perpendicular to
if not followed.
the Flat Reference Surface and slowly push in
until there is no gap. (Fig 3)
③
The number printed on the side of the Dedicated
Gauge is the Reference Value used for zero
adjustment. (Fig. 4)
Adjust the reading to match the Reference Value
by rotating the Bezel of the Dedicated Gauge.
(Fig. 5)
When the Gauge Reading matches the Reference
Value, the zero adjustment is complete.
※ Repeat the measurement several times to
confirm that the value is stable.
Setting Zero Point Using a Reference Standard
① Prepare an ID Chamfer Reference Standard for use.
② Hold the Measurement Head perpendicular to the Reference Standard and slowly push in until
there is no gap between the Reference Standard and the Measurement Head Reference Surface.
③ Adjust the reading to match the Reference Standard by rotating the Bezel of the Dedicated Gauge.
(Fig. 5) When the Gauge Reading matches the Reference Standard, the Zero Adjustment is complete.
※ Repeat the measurement several times to confirm that the Value is stable.
AFTER USE CARE, STORAGE
●
Clean outside surfaces regularly using a cloth to remove any dirt or contamination.
●
After use, place in a rust preventive bag or use a corrosion inhibiting oil for protection.
●
If surfaces are dirty, wipe with a clean cloth moistened with a cleaner such as Niigata Seiki STC-500.
●
Store in location protected from direct sunlight and humidity, and accessible only to authorized personnel.
Weight
(mm)
REPAIRS AND SERVICE
340
●
If Gauge does not operate properly, or if you have any
640
questions, please contact distributor or place of purchase.
●
Please note, manufacturer is unable to respond to inquires or
340
provide service directly. Please contact distributor or place of
640
purchase.
0
10
190
20
180
Meas. Head
30
170
90°
40
160
2:1
50
150
60
0.01 mm
140
20
38
22
36
24
70
130
34
26
32
28
80
30
120
90
110
100
(Fig.1)
Meas. Taper
Push in until there
is no gap
Diam.
(Fig.2)
※ Zero point is set at factory, but we recommend
periodic adjustment as required.
Meas. Head
90°
(Fig.3)
Value+
Ref.
Value
40
50
60
(Fig.4)
(Fig.5)
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL
http://www.niigataseiki.co.jp
Reference
Surface
Value−
0
10
190
20
180
30
170
160
2:1
150
0.01 mm
140
20
38
22
36
24
70
130
34
26
32
28
80
30
120
90
110
100
Bezel