S-LINE BORE GAUGE
ID Measuring
Instrument
Thank you for purchasing the S-LINE BORE GAUGE.
This product is a two-point mechanical instrument for measuring the ID of bores and holes relative to a reference
standard. Instrument can be used with a Dial Gauge, Digital Indicator Gauge, Electronic Sensor, etc.
● For safe and proper use of this product, please read this instruction manual before use and follow the procedures described.
Please keep manual where it is accessible to user for future reference.
● Keep this manual with the instrument if transferred or leased to a third party.
● For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page.
■
PART ID
Gauge
0
10
10
20
( sold
30
40
separately )
50
1. Gauge Mount
1
2. Shaft
3. Measurement Head
Centering Plate
4.
( Guide )
Washers
Extension Rod
6.
2
7. Extension Rod
Clamp Nut
3
4
5
6
7
SPECIFICATIONS
●
: 2 µm ●
: 2.5µm ●
Accuracy
Retrace Error
※ Accuracy specifications are for Instrument Body and do not include the Gauge. Total accuracy specification with Gauge
attached will be the sum of Instrument Body accuracy plus the Gauge accuracy.
●
s: Clamp Diameter ...φ8mm h6
Gauge Mount Specification
Gauge Insertion Length ( distance from probe tip to top of clamp surface ... ≥ 40mm
SCDI−8S
SCDI−12S
Model No.
Meas. Range
6-8
8-12
( mm )
Stroke Length
0.5
0.7
( mm )
7pcs.
9pcs.
Ex. Rod Quant./
6・6.4・6.8
8・8.5・9
12・13・14
Sizes
7・7.2・7.6
9.5・10・10.5
15・16・17
( mm )
8
11・11.5・12
18・19・20
Washer Quant. /
−
−
Sizes
( mm )
Weight
( g )
65
65
Probe replacement wrench included
Notes
Model
INSTRUCTION MANUAL
No.
SAFETY
20
30
Always follow the procedures specified below in order to prevent
40
50
harm to yourself or others, and to prevent damage to property.
CAUTION:
Indicates risk of personal injury or
property damage if not followed.
●
Use in accordance to the measuring range specified
in the manual for the measuring instrument model.
●
This is a precision instrument, handle with care.
●
Do not disassemble or modify.
●
Instrument is not waterproof or corrosion resistant;
Keep away from water and oils.
●
Use only with supplied Extension Rods and Washers.
●
Keep instrument away from direct sunlight and high
temperatures such as in a car, or near a stove or heat
source.
●
After use, remove dust and cutting chips, and apply
rust preventative oil to Extension Rods and Washers.
When not in use store in supplied storage case.
●
This product is for measuring inside diameter; use
only as directed. Improper use may cause accident or
injury.
: 0.5µm
Repeatability
SCDI−20S
SCDI−35S
SCDI−60S
SCDI−100S
12-20
18-35
35-60
50-100
0.9
1.3
1.3
1.4
9pcs.
9pcs.
6pcs.
11pcs.
18・20・22
35・39
50・55・60・65
24・26・28
44・49
70・ 75・80・85
30・32・34
54・59
90・95・100
1pcs.
2pcs.
2pcs.
3pcs.
1.0・2.0
0.5
0.5・1.0
2.0・3.0
3.0
95
85
175
190
PREPARATION
SCDI- *** S
① Select a combination of Extension Rod and Washers as close as possible to the ID of the part to be measured.
※ Must be withing measuring range of attached Gauge.
※ For SCDI-8S、 12S、 20S the Extension Rod and Washer attach directly to the Measuring Head.
For SCDI-35S、 60S、 100S、 160S、 attach the Extension Rod and Washer using the Clamp Nut.
② Attach a measuring instrument such as a dial gauge ( sold separately ) to the Instrument Body.
OPERATION
※SSCDI Series Bore Gauge is a comparative gauge and requires a Reference Master such as a ring gauge to set
up for comparative measurements.
※Prepare a Reference Master appropriate for the dimensions of the part to be measured.
Please Observe
※Before use, make sure the components on the Measurement Head are all securely attached and not loose.
SETTING THE 0-POINT
①Prepare a Ring Gauge to use as a reference standard for setting
the zero-point. Insert the Measurement Head into the ring gauge.
②In the direction perpendicular to the Ring Gauge axis, position the
Bore Gauge to measure diameter ⓐ shown in the cross section
( Fig. 1 ) . This is the maximum distance, and the Gauge will show
the minimum reading. The Guide moves to automatically position
the Gauge Head at this diameter when inserted.
③In the cross section shown in Figure 2, parallel the Ring Gauge
axis though diameter ⓐ, position the Bore Gauge to minimize the
distance ⓑ. In this position the Gauge will read the maximum
value.
This position is determined by manually moving the gauge and
noting the position where the Pointer shows the maximum value.
( Fig. 3 )
④The reading obtained at step ③ is the zero-point. Set the Gauge
to zero and the zero point is now set. ( Fig. 4 )
MEASUREMENT
Insert the Measurement Head of the Bore Gauge into the
object to be measured. As in step ③ of "Setting the 0-
Point" above, pivot the gauge while checking the pointer to
determine the diameter ⓑ where the gauge will show the
maximum value to determine the measurement reading.
This measurement will be the difference in diameter between
the part and the reference Ring Gauge.
AFTER USE CARE, STORAGE
●
Clean outside surfaces regularly using a cloth to remove any
SCDI−160S
dirt or contamination.
●
Use a cloth dampened with a cleaning solution if required for
100-160
excess dirt.
●
1.6
After use, place in a rust preventive bag or use a corrosion
inhibiting oil for protection.
●
7pcs.
Store in supplied case, protected from direct sunlight or
100・110・120
humid environments, and accessible only to authorized
130・140・150
personnel.
160
REPAIRS AND SERVICE
4pcs.
1.0・2.0
●
If Gauge does not operate properly, or if you have any questions,
3.0・6.0
please contact distributor or place of purchase.
530
●
Please note, manufacturer is unable to respond to inquires or provide
service directly. Please contact distributor or place of purchase.
Fig.1
0
10
10
20
20
30
30
40
40
50
50
�
Fig.2
Fig.3
ⓑ
Set to Zero
0
0
10
10
10
10
20
20
20
20
30
30
30
30
40
40
40
40
50
50
50
50
Fig.4
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL
http://www.niigataseiki.co.jp