Environmental Specifications; Air Quality Requirements - ACRONIS Cyber Appliance Quick Start Manual

Hide thumbs Also See for Cyber Appliance:
Table of Contents

Advertisement

Max inrush, A
Input current
Power supply efficiency
(Platinum class)
Input power factor correction
1
Tested at 230 Vac, 50 Hz and 115 Vac, 60 Hz. The input power factor is greater than values in the
table at power supply's rated output and meets Energy Star® requirements.
8.2  Environmental specifications
Acronis Cyber Appliance environmental specifications are listed in the following tables.
Store temperature
Store temperature gradient
Operating temperature
Operating temperature gradient
Relative humidity percentage range for storage
Relative humidity percentage range for operating
Vibration for storage
Vibration for operating
Shock for storage
Shock for operating
Altitude for storage
Altitude for operating
8.2.1  Air quality requirements
The air must be free of:
 
Corrosive dust and corrosive contaminants
l
 
Conductive dust and conductive particles (such as zinc whiskers)
l
31
40
AC input
100–127 Vac, 8.8 A
10% load
80%
1
Output power
Power factor
Max. current
200–240 Vac, 4.3 A
20% load
50% load
90%
94%
20% load
50% load
>0.80
>0.95
-40°C to 85°C (-40°F to 185°F)
20°C (68°F) per hour
10°C to 35°C (50°F to -95°F)
20°C (68°F) per hour
10% ~ 95% (non-condensing)
10% ~ 85% (non-condensing)
1.87 Grms (10-500 Hz)
0.26 Grms (5-350 Hz)
65G for 2ms
5G
12,000m (39,370 ft)
3,048m (10,000 ft)
© Acronis International GmbH, 2003-2021
100% load
91%
100% load
>0.95