Gree GWH07QAXA-K6DNC2Z/O Owner's Manual
Hide thumbs Also See for GWH07QAXA-K6DNC2Z/O:

Advertisement

Change for life
Owner's Manual
Original Instructions
Split Air Conditioner
CONTENTS
......................................................................................
..................................................................................................
.........................................................................................
.......................................................................................
......................................................................................
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent
or visit www.gree.com or send an email to global@cn.gree.com for
the electronic version.
NOTE:
Actual product may be different from graphics,
please refer to actual products.
............................................................................
..................................................................
01
05
06
08
10
11
14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GWH07QAXA-K6DNC2Z/O and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gree GWH07QAXA-K6DNC2Z/O

  • Page 1: Table Of Contents

    Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.gree.com or send an email to global@cn.gree.com for the electronic version. NOTE:...
  • Page 2 GWH07QAXA-K6DNC2Z/O GWH18AUDXE-K6DNA1B/O GWH18QDXB-K6DNC2Z/O GWH18AUDXE-K6DNA2C/O GWH24QDXE-K6DNB2Z/O GWH24AUDXF-K6DNA1B/O GWH24QDXE-K6DNC2Z/O GWH12AWBXB-K6DNA3F/O GWH09YCXB-K6DNA1C/O GWH12AWCXB-K6DNA3E/O GWH12YCXD-K6DNA1B/O GWH12YCXD-K6DNA1Z/O GWH24YEXF-K6DNA1D/O GWH24YEXF-K6DNA1Z/O GWH09ANCXB-K6DNA1A/O GWH12ANCXD-K6DNA1A/O GWH09AECXB-K6DNA1A/O GWH12AECXD-K6DNA1A/O GWH09AKCXD-K6DNA1A/O GWH12AKCXD-K6DNA1A/O GWH09AGAXB-K6DNA1B/O GWH09AGBXB-K6DNA1A/O GWH12AGBXB-K6DNA1A/O GWH12AGBXB-K6DNA1Z/O GWH12AGCXB-K6DNA1A/O GWH18AGDXB-K6DNA1Z/O GWH24AGDXE-K6DNA1Z/O GWH09APAXE-K6DNA3A/O GWH12APAXE-K6DNA3A/O GWH18APAXH-K6DNA3A/O GWH12ATBXB-K6DNA1D/O GWH12ATCXB-K6DNA1A/O GWH12ATCXB-K6DNA1D/O GWH09AVCXB-K6DNA1B/O GWH12AVCXD-K6DNA1A/O GWH18AVDXE-K6DNA1A/O GWH24AVEXF-K6DNA1A/O GWH12AUCXD-K6DNA1C/O GWH18AUDXE-K6DNA1A/O...
  • Page 3: Explanation Of Symbols

    Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
  • Page 4 The refrigerant This appliance is not intended for use by persons Before install the Appliance filled (including children) with reduced physical, sensory appliance, read with flammable t i l i the installation gas R32. knowledge, unless they have been given superv- manual first.
  • Page 5: Maintenance Notes

    Safety operation of flammable refrigerant Installation notes Check whether there is fire source or potential fire source in the maintenance area. The air conditioner must be installed in a room - The naked flame is prohibited in the mainte- that is larger than the minimum room area. The nance area;...
  • Page 6: Safety Precautions

    Safety precautions WARNING Installation Installation or maintenance The grounding resistance must be performed by qua- should comply with nation- lified professionals. al electric safety regula- The appliance shall be in- tions. stalled in accordance with Air Conditioner should be national wiring regulations. properly grounded.
  • Page 7 Safety precautions CAUTION Installation Instructions for installation For the air conditioner with- and use of this product are out plug, a circuit breaker provided by the manufac- must be installed in the turer. line. Select a location which is The yellow-green wire in out of reach for children air conditioner is ground- and far away from animals...
  • Page 8: Operation And Maintenance

    Safety precautions WARNING Operation and Maintenance tioner to multi-purpose soc- This appliance can be used ket. Otherwise, it may cau- by children aged from 8 se fire hazard. years and above and per- Do disconnect power supp- sons with reduced physi- ly when cleaning air condi- cal, sensory or mental ca- tioner.
  • Page 9 Safety precautions CAUTION Operation and Maintenance frequently. Do not spill water on the re- Air conditioner gives off mote controller, otherwise burning smell. the remote controller may Indoor unit is leaking. be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
  • Page 10: Parts Name

    Parts name Outdoor Unit air inlet air outlet NOTE ● Actual product may be different from above graphics, please refer to actual product.
  • Page 11: Installation Notice

    Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
  • Page 12: Safety Precaution

    Selection of installation location Requirements for electric connection Basic requirement 8.The temperature of refrigerant circuit will be hi- Installing the unit in the following places may cau- gh, please keep the interconnection cable away se malfunction. If it is unavoidable, please consu- from the copper tube.
  • Page 13: Installation Of Outdoor Unit

    Installation of outdoor unit Step 1: Fix the support of outdoor unit (select it according to the actual inst- drain vent allation situation) chassis Select installation location according to outdoor drain joint Drain hose the house structure. Step 3: Fix the support of outdoor unit on the sele- cted location with expansion screws.
  • Page 14 Step 6: Tighten the union nu t with torque wrench Neaten the pipes by referring to the sheet below. The pipes should be placed along the wall, bent Tightening torque(N m) Hex nut diameter reasonably and hidden possibly. Min. semidiam- 1/4'' 15~20 eter of bending the pipe is 10cm.
  • Page 15: Test And Operation

    Test and operation Check after installation ● Check according to the following requirement Use vacuum pump after finishing installation. Remove the valve caps on the liquid valve and Items to be checked Possible malfunction gas valve and the nut of refrigerant charging vent. 2.
  • Page 16: Configuration Of Connection Pipe

    Configuration of connection pipe Additional refrigerant charging amount for R32 Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe. For the unit with standard connection pipe of 5m, there is no limitation for the min length of con- nection pipe.
  • Page 17 B: Remove the burrs smooth surface Remove the burrs with shaper and prevent the ● burrs from getting into the pipe. improper expanding pipe shaper leaning damaged crack uneven surface thickness downwards the length is equal C: Put on suitable insulating pipe D: Put on the union nut Remove the union nut on the indoor connection ●...
  • Page 18: Working Temperature Range

    Working temperature range GWH07QAXA-K6DNC2Z/O GWH24AGDXE-K6DNA1Z/O GWH09ANCXB-K6DNA1A/O GWH09AVCXB-K6DNA1B/O(LCLH) GWH09AGBXB-K6DNA1A/O GWH12ATBXB-K6DNA1D/O GWH12ANCXD-K6DNA1A/O GWH12AVCXD-K6DNA1A/O(LCLH) GWH09AGAXB-K6DNA1B/O GWH12ATCXB-K6DNA1D/O GWH09YCXB-K6DNA1C/O(LCLH) GWH18AVDXE-K6DNA1A/O(LCLH) GWH12AGBXB-K6DNA1A/O GWH18QDXB-K6DNC2Z/O GWH12YCXD-K6DNA1Z/O(LCLH) GWH24AVEXF-K6DNA1A/O(LCLH) GWH12AGBXB-K6DNA1Z/O GWH24QDXE-K6DNB2Z/O GWH12YCXD-K6DNA1B/O(LCLH) GWH12ATCXB-K6DNA1A/O(LCLH) GWH24QDXE-K6DNC2Z/O GWH12AUCXD-K6DNA1C/O(LCLH) GWH24YEXF-K6DNA1D/O(LCLH) GWH12AWBXB-K6DNA3F/O GWH18AUDXE-K6DNA1A/O(LCLH) GWH24YEXF-K6DNA1Z/O GWH12AWCXB-K6DNA3E/O GWH24AUDXF-K6DNA1B/O(LCLH) GWH18AUDXE-K6DNA1B/O(LCLH) Indoor side Outdoor side GWH18AUDXE-K6DNA2C/O(LCLH) DB/WB(°C) DB/WB(°C) Indoor side Outdoor side DB/WB(°C)
  • Page 19: Specialist's Manual

    Specialist’s Manual The following checks shall be applied to instal- General work area lations using flammable refrigerants: All maintenance staff and others working in the – the charge size is in accordance with the room size local area shall be instructed on the nature of work within which the refrigerant containing parts are in- being carried out.
  • Page 20 Specialist’s Manual - the actual refrigerant charge is in accordance with incorrect fitting of glands, etc. the room size within which the refrigerant contain- – Ensure that the apparatus is mounted securely. ing parts are installed; – Ensure that seals or sealing materials have not de- - the ventilation machinery and outlets are operat- graded to the point that they no longer serve the pur- ing adequately and are not obstructed;...
  • Page 21 Specialist’s Manual most refrigerants but the use of detergents contain- does not occur when using charging equipment. Hoses or lines shall be as short as possible to ing chlorine shall be avoided as the chlorine may minimise the amount of refrigerant contained in react with the refrigerant and corrode the copper them.
  • Page 22 Specialist’s Manual the cylinder, even temporarily. not in cylinders. If compressors or compressor oils are to be remov- j) When the cylinders have been filled correctly and ed, ensure that they have been evacuated to an ac- the process completed, make sure that the cylinders ceptable level to make certain that flammable refri- and the equipment are removed from site promptly gerant does not remain within the lubricant.
  • Page 23 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com Web: www.gree.com 600005064514...