livin flame Skomo User And Installation Instructions Manual page 64

Table of Contents

Advertisement

Available languages

Available languages

The fire goes out or the
stove stops automatically
The air fan convention
(ambient air) never stops
The stove does not light.
The manufacturer of the stove any liability and will void the warranty terms of
the product for any inconvenience caused by not following the rules described
above. Any work of service center will be borne by the applicant if they are not
complied with these instructions.
30
1. The pellet tank is empty
2. No power
3. Pellets not being fed
4. Excessive deposit of ashes in the
grate
5. Intervention probe temperature
safety of the pellet
6. Cochlea blocked by dirt
7. The door is not closed properly or
gaskets worn
8. Pellet inadequate
9. Low pellet
10. Chimney or drain clogged with
nests or foreign bodies
11. Pressure switch cuts
12. Smoke extraction motor failure
13. Alarm active
1. Temperature sensor temperature
control defective or broken
2. Smoke probe fails
1. Lack of electricity
2. Probe pellets in bulk
3. Fuse blown
4. Pressure switch broken (lockout
indicated)
5. Smoke outlet or duct clogged
1. Fill the tank with pellets
2. Check plug and presence electricity
3. Fill the tank with pellets
4. Clean the brazier
5. Let the stove cool down completely, reset the manual
reset and restart the stove. If the problem persists, contact
your authorized service representative
6. Pull the plug, empty the tank, remove any foreign objects
7. Close the door or replace the gaskets with original
8. Change the type of pellet recommended by the
manufacturer. Sometimes, depending on the type,
the stage of adjustment of the parameters need
to vary the level relating to the loading of pellets
9. Increase the level in the parameter for the pellet feed.
To check the flow of fuel from technical authorized
10. Eliminate all foreign matter from the chimney Clean
the smoke duct. Perform periodic cleaning.
11. Verify potential smoke duct is blocked and if
the pressure switch is working properly
12. Check and replace the motor if necessary
13. See paragraph alarms
1. Check the operation of the sensor and replace if
necessary
2. Replace smoke probe
1. Check that the electrical outlet is plugged in and the
power switch to "I"
2. Lockout by resetting the rear thermostat, replace the
thermostat if it happens again
3. Replace the fuse
4. Replace the pressure
5. Clean the smoke outlet and / or smoke duct

Hide quick links: