Problems And Solutions; Any Inconvenience And Solutions - livin flame Skomo User And Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Problems and solutions

All repairs must be carried out exclusively by a specialised technician, with the
stove completely cold and the electric plug pulled out. Is prohibited from any
unauthorized modifi cation to the device and the replacement of parts with
other non-original. The operations marked in bold type must be carried out by
specialised personnel.

Any inconvenience and solutions

Given that all stoves are tested in their parts handling and work and therefore are delivered in perfect physical
condition and operation, it should be remembered that the transport, unloading, handling, misuse or poor
maintenance, can be causes of drawbacks.
The main problems may be solved by reading the table below.
If after doing as hereinafter described the problem is not resolved, contact your authorized service center.
PROBLEM
Display off and buttons
are not working
Remote ineffi cient
Failure to ignite
the stove
Smoke comes from the
grill
Hot air fan is not working
POSSIBLE CAUSE
1. Power failure in the network
2. Switch back off
3. Display defective
4. Fault in the connection of the
display with the card
5. Fuse board interrupted
6. Card defective
1. Too far from the stove
2. No batteries in the remote
3. The remote control is broken
1. Excessive accumulation of ash in
the grate
2. Incorrect ignition procedure
1. Accidental electrical blackout
1. The stove has not yet been heated
REMEDY
1. Check that the power cord is connected
2. Use the switch back to operate it
3. Unplug the stove from the power outlet for about one
minute and then turn on. If the problem persists, contact
an authorized service center
4. Check that the display and board are properly
connected. Contact your authorized service center
5. Contact an authorized service center
6. Contact an authorized service center
1. Move closer to the stove
2. Check and change the batteries
3. Replace the remote control
1. Clean the grate
2. Repeat the ignition procedure. If sists, contact your
authorized service center
1. In case of ignition phase interrupted and momentary
interruption of the fan, can occur slight amount of smoke
1. Wait until the conclusion of the ignition cycle.
Arrived in temperature, the fan will start automatically.
If the problem persists, contact your authorized service
center.